Bestsellers

TN52TOM01

Brand: Huawei
Model: TOM

Description: 8*Multi-rate Ports Service Processing Board

Part Number: 03030LGC
Quantity:


HUAWEI

TN52TOM01

TOM

The TN52TOM01 is a multi-rate ports service processing board. The TN52TOM01 can be used on the OSN 3800, OSN 6800, OSN 8800 equipment to be used in different application scenarios.

2.67 Gbit/s Multirate(eSFP CWDM)-80 km, 2.67 Gbit/s Multirate (eSFP DWDM)-120 km

 

Basic Functions Performs conversion between client services at rates within the range of 100 Mbit/s to 2.67 Gbit/s and ODU0 or ODU1 signals when functioning as a tributary board.
Performs conversion between client services at rates within the range of 100 Mbit/s to 2.67 Gbit/s and OTU1 signals when functioning as a tributary-line board.
Supports convergence of multiple services into one ODU0 or ODU1 signal.The TOM board supports multiple application scenarios.
OTN function The mapping process is compliant with ITU-T G.7041 and ITU-T G.709. Supports the frame format and overhead processing by referring to the ITU-T G.709.
Supports the SM and TCM functions at the OTU1 and ODU1 layers on the WDM side.
Supports the PM and TCM non-intrusive monitoring functions at the ODU1 layer.
Supports the PM functions at the ODU1 layers.
TN52TOM supports the PM function at the ODU0 layer.
ALS function Supports the ALS function on the client side.
ESC function Supported.
Optical-layer ASON Not supported
PRBS function Supports the PRBS function on the client side and WDM side.
NOTE
The PRBS function on the client side is supported only when the client-side service type is STM-1/OC-3, STM-4/OC-12, or STM-16/OC-48.
LPT function The board supports the LPT function only when the client-side service type is FE or GE.
Protection Schemes OptiX OSN 3800/OptiX OSN 6800:
Supports SW SNCP.
Supports client 1+1 protection.
Supports intra-board 1+1 protection.
Supports OWSP protection.
Supports ODUk SNCP.
Supports tributary SNCP protection.
Supports MS SNCP protection.
OptiX OSN 8800:
Supports SW SNCP.
Supports client 1+1 protection.
Supports intra-board 1+1 protection.
Supports OWSP protection.
Supports ODUk SNCP.
Supports tributary SNCP protection.
NOTE
When the board receives OTN services, SDH/SONET services the board supports tributary SNCP protection. For the TN52TOM board, ODU0 tributary SNCP protection is supported only in ODU1_ODU0 mode (OTU1->ODU1->ODU0).
Alarms and performance events monitoring Monitors BIP8 bytes (Poisson mode or Bursty mode) to help locate line failures.
Monitors B1 bytes to help locate faults.
Monitors parameters such as the bias current, temperature, and optical power of the laser.
Monitors OTN alarms and performance events.
Supports the remote monitoring (RMON) of Ethernet services.
NOTE
Only the TN11TOM supports Poisson mode.
Cross-connect function OptiX OSN 8800:
TN52TOM
Supports the cross-connection of four ODU1 signals or eight ODU0 signals through the cross-connect bus on the backplane and the cross-connect board.
OptiX OSN 6800:
TN52TOM
Supports the cross-connection of four ODU1 signals between the TOM and the cross-connect board.
Supports the cross-connection of six channels of GE signals to the paired slots through the backplane.
Supports the transmission of six signals at the rate between 100 Mbit/s and 2.5 Gbit/s to the paired slots through the backplane.
OptiX OSN 3800:
Supports the cross-connection of four channels of ODU1 signals between one board of the mesh group (consisting of four boards) and any two boards in the non-paired slots of the four slot mesh group, that is, supports the ODU1 cross connection between slots IU2 and IU4, slots IU2 and IU5, slots IU3 and IU4, and slots IU3 and IU5.
Supports the cross-connection of six channels of GE signals between one board of the mesh group (consisting of four boards) and the paired slot of the four-slot mesh group, that is, supports the GE cross-connection between slots IU2 and IU3 and slots IU4 and IU5.
Supports the cross-connection of six signals at the rate between 100 Mbit/s and 2.5 Gbit/s, except ODU1 signals, between one board of the mesh group (consisting of four boards) and the paired slot of the four-slot mesh group, that is, supports the cross-connection of six signals at the rate between 100 Mbit/s and 2.5 Gbit/s, except ODU1 signals, between slots IU2 and IU3 and slots IU4 and IU5.
Electrical-layer ASON Supported by the TN52TOM.
Loopback function WDM side: Supported inloop and outloop
Client side:Supported inloop and outloop
Test frames The board supports the test frame function only when the client-side service type is FE or GE.
Board Name TN52TOM01
Client-Side Pluggable Optical Module FE: Ethernet service at a rate of 125 Mbit/s
GE: Ethernet service at a rate of 1.25 Gbit/s
OTU1: OTN service at a rate of 2.67 Gbit/s
STM-1/OC-3: SDH/SONET service at a rate of 155.52 Mbit/s
NOTE
When the TOM board transmits GE electrical signals, to facilitate fiber routing, you are advised to install electrical modules at the RX1/TX1 and RX2/TX2 ports.
The TOM board supports access of SDI, HD-SDI, and DVB-ASI electrical signals. When the board is used to accept these electrical signals, a digital video O/E converter must be used for O/E or E/O conversion and the optical module of the converter must agree with the board optical module specifications. The digital video O/E converter is a third-party device. Customers can purchase a digital video O/E converter by themselves.
STM-4/OC-12: SDH/SONET service at a rate of 622.08 Mbit/s
STM-16/OC-48: SDH/SONET service at a rate of 2.5 Gbit/s
FC100: SAN service at a rate of 1.06 Gbit/s
FC200: SAN service at a rate of 2.12 Gbit/s
FICON: SAN service at a rate of 1.06 Gbit/s
FICON Express: SAN service at a rate of 2.12 Gbit/s
HD-SDI: Bit-serial digital interface for high-definition television systems at a rate of 1.49 Gbit/s
DVB-ASI: Video service at a rate of 270 Mbit/s
SDI: Serial digital interface at a rate of 270 Mbit/s
ESCON: SAN service at a rate of 200 Mbit/s
FDDI: SAN service at a rate of 125 Mbit/s
WDM-Side Pluggable Optical Module 2.67 Gbit/s Multirate(eSFP CWDM)-80 km
2.67 Gbit/s Multirate(eSFP DWDM)-120 km
I-16-2 km
S-16.1-15 km
L-16.1-40 km
L-16.2-80 km
Line code pattern NRZ
Dimensions (mm) 264.6 (10.4 in.) x 25.4 (1.0 in.) x 220 (8.7 in.)
Net Weight (kg) 1.5
Volume weight (kg) 3
<p><span style="font-size:14px"><span style="font-family:tahoma,geneva,sans-serif"><span style="background-color:rgb(255, 255, 255); color:rgb(51, 51, 51)">Double 10G Line Service Processing Board(AFEC,Tunable), 50GHz(800ps/nm,Rx1_PIN,Tx1_-3dBm~+2dBm,LC)</span></span></span></p>
<p><span style="font-size:14px"><span style="font-family:tahoma,geneva,sans-serif">10 *10G Tributary Service Processing Board</span></span></p>
<p><span style="font-size:14px"><span style="font-family:tahoma,geneva,sans-serif">Double 10G Line Service Processing Board(AFEC,Super WDM,Tunable), 50GHz(800ps/nm,Rx1_PIN,Tx1_-3dBm~+2dBm,LC)</span></span></p>
Functions and Features
Basic Functions Performs conversion between client services at rates within the range of 100 Mbit/s to 2.67 Gbit/s and ODU0 or ODU1 signals when functioning as a tributary board.
Performs conversion between client services at rates within the range of 100 Mbit/s to 2.67 Gbit/s and OTU1 signals when functioning as a tributary-line board.
Supports convergence of multiple services into one ODU0 or ODU1 signal.The TOM board supports multiple application scenarios.
OTN function The mapping process is compliant with ITU-T G.7041 and ITU-T G.709. Supports the frame format and overhead processing by referring to the ITU-T G.709.
Supports the SM and TCM functions at the OTU1 and ODU1 layers on the WDM side.
Supports the PM and TCM non-intrusive monitoring functions at the ODU1 layer.
Supports the PM functions at the ODU1 layers.
TN52TOM supports the PM function at the ODU0 layer.
ALS function Supports the ALS function on the client side.
ESC function Supported.
Optical-layer ASON Not supported
PRBS function Supports the PRBS function on the client side and WDM side.
NOTE
The PRBS function on the client side is supported only when the client-side service type is STM-1/OC-3, STM-4/OC-12, or STM-16/OC-48.
LPT function The board supports the LPT function only when the client-side service type is FE or GE.
Protection Schemes OptiX OSN 3800/OptiX OSN 6800:
Supports SW SNCP.
Supports client 1+1 protection.
Supports intra-board 1+1 protection.
Supports OWSP protection.
Supports ODUk SNCP.
Supports tributary SNCP protection.
Supports MS SNCP protection.
OptiX OSN 8800:
Supports SW SNCP.
Supports client 1+1 protection.
Supports intra-board 1+1 protection.
Supports OWSP protection.
Supports ODUk SNCP.
Supports tributary SNCP protection.
NOTE
When the board receives OTN services, SDH/SONET services the board supports tributary SNCP protection. For the TN52TOM board, ODU0 tributary SNCP protection is supported only in ODU1_ODU0 mode (OTU1->ODU1->ODU0).
Alarms and performance events monitoring Monitors BIP8 bytes (Poisson mode or Bursty mode) to help locate line failures.
Monitors B1 bytes to help locate faults.
Monitors parameters such as the bias current, temperature, and optical power of the laser.
Monitors OTN alarms and performance events.
Supports the remote monitoring (RMON) of Ethernet services.
NOTE
Only the TN11TOM supports Poisson mode.
Cross-connect function OptiX OSN 8800:
TN52TOM
Supports the cross-connection of four ODU1 signals or eight ODU0 signals through the cross-connect bus on the backplane and the cross-connect board.
OptiX OSN 6800:
TN52TOM
Supports the cross-connection of four ODU1 signals between the TOM and the cross-connect board.
Supports the cross-connection of six channels of GE signals to the paired slots through the backplane.
Supports the transmission of six signals at the rate between 100 Mbit/s and 2.5 Gbit/s to the paired slots through the backplane.
OptiX OSN 3800:
Supports the cross-connection of four channels of ODU1 signals between one board of the mesh group (consisting of four boards) and any two boards in the non-paired slots of the four slot mesh group, that is, supports the ODU1 cross connection between slots IU2 and IU4, slots IU2 and IU5, slots IU3 and IU4, and slots IU3 and IU5.
Supports the cross-connection of six channels of GE signals between one board of the mesh group (consisting of four boards) and the paired slot of the four-slot mesh group, that is, supports the GE cross-connection between slots IU2 and IU3 and slots IU4 and IU5.
Supports the cross-connection of six signals at the rate between 100 Mbit/s and 2.5 Gbit/s, except ODU1 signals, between one board of the mesh group (consisting of four boards) and the paired slot of the four-slot mesh group, that is, supports the cross-connection of six signals at the rate between 100 Mbit/s and 2.5 Gbit/s, except ODU1 signals, between slots IU2 and IU3 and slots IU4 and IU5.
Electrical-layer ASON Supported by the TN52TOM.
Loopback function WDM side: Supported inloop and outloop
Client side:Supported inloop and outloop
Test frames The board supports the test frame function only when the client-side service type is FE or GE.
Technical Specification
Board Name TN52TOM01
Client-Side Pluggable Optical Module FE: Ethernet service at a rate of 125 Mbit/s
GE: Ethernet service at a rate of 1.25 Gbit/s
OTU1: OTN service at a rate of 2.67 Gbit/s
STM-1/OC-3: SDH/SONET service at a rate of 155.52 Mbit/s
NOTE
When the TOM board transmits GE electrical signals, to facilitate fiber routing, you are advised to install electrical modules at the RX1/TX1 and RX2/TX2 ports.
The TOM board supports access of SDI, HD-SDI, and DVB-ASI electrical signals. When the board is used to accept these electrical signals, a digital video O/E converter must be used for O/E or E/O conversion and the optical module of the converter must agree with the board optical module specifications. The digital video O/E converter is a third-party device. Customers can purchase a digital video O/E converter by themselves.
STM-4/OC-12: SDH/SONET service at a rate of 622.08 Mbit/s
STM-16/OC-48: SDH/SONET service at a rate of 2.5 Gbit/s
FC100: SAN service at a rate of 1.06 Gbit/s
FC200: SAN service at a rate of 2.12 Gbit/s
FICON: SAN service at a rate of 1.06 Gbit/s
FICON Express: SAN service at a rate of 2.12 Gbit/s
HD-SDI: Bit-serial digital interface for high-definition television systems at a rate of 1.49 Gbit/s
DVB-ASI: Video service at a rate of 270 Mbit/s
SDI: Serial digital interface at a rate of 270 Mbit/s
ESCON: SAN service at a rate of 200 Mbit/s
FDDI: SAN service at a rate of 125 Mbit/s
WDM-Side Pluggable Optical Module 2.67 Gbit/s Multirate(eSFP CWDM)-80 km
2.67 Gbit/s Multirate(eSFP DWDM)-120 km
I-16-2 km
S-16.1-15 km
L-16.1-40 km
L-16.2-80 km
Line code pattern NRZ
Mechanical Specifications
Dimensions (mm) 264.6 (10.4 in.) x 25.4 (1.0 in.) x 220 (8.7 in.)
Net Weight (kg) 1.5
Volume weight (kg) 3