CXPC

The TND2CXPC is a system control, cross-connect and protocol processing board. The TND2CXPC can be used on the OptiX PTN 950 equipment to provides service grooming and clock input/output functions

12 Gbit/s

Basic Functions Cross-connect capacity: 12 Gbit/s
Supports switching, control, and clock management.
Supports the board-level 1+1 backup function
APS Supports MPLS Tunnel APS.
Supports 1:1 PW APS with dual-ended switching.
MPLS Tunnel OAM Supported
PW OAM Supported
BFD Supports BFD with a period of 3.3 ms, 10 ms, 20 ms, 50 ms, 100 ms, or 1s.
Tact switches Provides two tact switches. When you rotate the ejector levers to remove the board, the two tact switches are triggered to start the active/standby protection switching.
Auxiliary interface function Provides two clock/time input/output interfaces and provides the synchronization time source and clock source for the equipment. The CLK1/TOD1 port can be used to monitor AC input/output of the EPS30–4815 power supply system.
Provides one 10 Mbit/s/100 Mbit/s auto-sensing Ethernet NM interface or NM serial interface for communication with the NMS.
Provides one alarm input and output interface.
Board Name TND2CXPC
Dimensions (mm) 22.86 (H) x 225.75 (D) x 193.80 (W)
Net Weight (kg) 0.62
Volume weight (kg) 3
<p><span style="font-size:14px"><span style="font-family:tahoma,geneva,sans-serif">System Control, Cross-connect and Protocol Processing Board</span></span></p>
Functions and Features
Basic Functions Cross-connect capacity: 12 Gbit/s
Supports switching, control, and clock management.
Supports the board-level 1+1 backup function
APS Supports MPLS Tunnel APS.
Supports 1:1 PW APS with dual-ended switching.
MPLS Tunnel OAM Supported
PW OAM Supported
BFD Supports BFD with a period of 3.3 ms, 10 ms, 20 ms, 50 ms, 100 ms, or 1s.
Tact switches Provides two tact switches. When you rotate the ejector levers to remove the board, the two tact switches are triggered to start the active/standby protection switching.
Auxiliary interface function Provides two clock/time input/output interfaces and provides the synchronization time source and clock source for the equipment. The CLK1/TOD1 port can be used to monitor AC input/output of the EPS30–4815 power supply system.
Provides one 10 Mbit/s/100 Mbit/s auto-sensing Ethernet NM interface or NM serial interface for communication with the NMS.
Provides one alarm input and output interface.
Technical Specification
Board Name TND2CXPC
Mechanical Specifications
Dimensions (mm) 22.86 (H) x 225.75 (D) x 193.80 (W)
Net Weight (kg) 0.62