ETP48200-C5B4

0 Reviews Write a review
SKU2026020
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

The Huawei ETP48200-C5B4 is embedded telecom power systems that supply power to –48 V DC communications equipment with a maximum current of 200 A.

Description

Overview

ETP48200-C5B4 is embedded telecom power systems that supply power to –48 V DC communications equipment with a maximum current of 200 A.

 

ETP48200-C5B4 Appearance

ETP48200 C5B4

(1) LLVD circuit breakers

(2) AC output circuit breaker and terminal

(3) AC SPD

(4) Ground screw

(5) AC input circuit breaker and terminal

(6) SMU02B

(7) Space for rectifiers

(8) BLVD circuit breakers

(9) Battery circuit breakers

(10) Battery switch (behind the cover)

(11) UIM02C

 

System Configurations

Item

ETP48200-C5B4

Subrack

  • 3 U power distribution space
  • 1 U SMU
  • 1 U rectifier space

PDU

  • AC power distribution: AC input circuit breaker and AC output circuit breaker
  • DC power distribution: battery low voltage disconnection (BLVD) route, load low voltage disconnection (LLVD) route, and battery route

Rectifier

A maximum of four R4850N2s or R4850G2s

SMU

SMU02B

User interface module (UIM)

UIM02C

Surge protective device (SPD)

AC surge protection: nominal lightning strike discharge current of 30 kA (8/20 µs), maximum lightning strike discharge current of 60 kA (8/20 µs)

DC surge protection: 10 kA (8/20 µs) in differential mode, 20 kA (8/20 µs) in common mode

ETP48200-C5B4 Datasheet

Item

ETP48200-C5B4

Specifications

Environment

Operating temperature

–40°C to +65°C

Transport temperature

–40°C to +70°C

Storage temperature

–40°C to +70°C

Operating humidity

5%–95% RH (non-condensing)

Storage humidity

5%–95% RH (non-condensing)

Altitude

0 m to 4000 m

(When the altitude ranges from 3000 m to 4000 m, the operating temperature decreases by 1°C for each additional 200 m.)

AC input

Input system

ETP48200-C5B4: 220/380 V AC three-phase, compatible with 220 V AC single-phase

ETP48200-C5B5: 110 V AC dual-live-wire, compatible with 220 V AC single-phase

Input frequency

45–66 Hz (rated frequency: 50 Hz or 60 Hz)

Power factor (PF)

≥ 0.99 (rated load power)

DC output

Output voltage range

–42 V DC to –58 V DC

Default output voltage

–53.5 V DC

Maximum output power

12000 W (supports N+1 backup and keeps long-term operating current output within 150 A)

Regulated voltage precision

≤ ±1% (The output voltage is within 53.5 V DC ±0.1 V DCunder 50% loads.)

Peak-to-peak noise voltage

≤ 200 mV (rated input voltage and load)

Telephone noise weighting voltage

≤ 2 mV (300–3400 Hz, input power ≤ 264 V AC)

Current imbalance

≤ ±5% (50%–100% load)

AC input protection

AC input overvoltage protection threshold

≥ 300 V AC

AC input overvoltage recovery threshold

290 V AC to 300 V AC

AC input undervoltage protection threshold

≤80 V AC

AC input undervoltage recovery threshold

80 V AC to 90 V AC

DC output protection

DC output overvoltage protection threshold

–58.5 V DC to –60.5 V DC

Electromagnetic compatibility (EMC)

Conducted emission (CE)

AC port: EN 55022 class B

DC port: EN 55022 class A

Radiated emission (RE)

EN 55022 class B

Harmonic current

IEC 61000-3-12

Voltage fluctuation and flick

IEC 61000-3-3

Electrostatic discharge (ESD)

IEC 61000-4-2

Shell port: contact discharge of 6 kV and air discharge of 8 kV; signal port: contact discharge of 2 kV

Electrical fast transient (EFT)

IEC 61000-4-4

AC and DC power ports: 2 kV

Radiated susceptibility (RS)

IEC 61000-4-3

10 V/m field strength

Conducted susceptibility (CS)

IEC 61000-4-6

Power port: 10 V; signal port: 3 V

Surge immunity

IEC 61000-4-5

AC and DC power ports: 2 kV (8/20 µs) in differential mode, 4 kV (8/20 µs) in common mode

Voltage dips immunity (DIP)

IEC 61000-4-11

Others

Surge protection

AC power port: nominal lightning strike discharge current of 30 kA (8/20 µs), maximum lightning strike discharge current of 60 kA (8/20 µs)

DC power port: 10 kA (8/20 µs) in differential mode, 20 kA (8/20 µs) in common mode

Safety and regulatory design

IEC/EN60950-1 and GB4943, TUV and CE certifications

Mean time between failures (MTBF)

200,000 hours

Structure

Power system dimensions (H x W x D)

219.5 mm x 482.6 mm x 330 mm

Weight

≤ 20 kg (excluding rectifiers)

Protection level

IP20

Installation mode

Installed in a 19-inch rack

Cabling

Routed in and out from the top

Maintenance mode

Maintained from the front

Heat dissipation

Nature heat dissipation

Additional information

Brand

Huawei

ETP48200-C5B4 Datasheet

Item

ETP48200-C5B4

Specifications

Environment

Operating temperature

–40°C to +65°C

Transport temperature

–40°C to +70°C

Storage temperature

–40°C to +70°C

Operating humidity

5%–95% RH (non-condensing)

Storage humidity

5%–95% RH (non-condensing)

Altitude

0 m to 4000 m

(When the altitude ranges from 3000 m to 4000 m, the operating temperature decreases by 1°C for each additional 200 m.)

AC input

Input system

ETP48200-C5B4: 220/380 V AC three-phase, compatible with 220 V AC single-phase

ETP48200-C5B5: 110 V AC dual-live-wire, compatible with 220 V AC single-phase

Input frequency

45–66 Hz (rated frequency: 50 Hz or 60 Hz)

Power factor (PF)

≥ 0.99 (rated load power)

DC output

Output voltage range

–42 V DC to –58 V DC

Default output voltage

–53.5 V DC

Maximum output power

12000 W (supports N+1 backup and keeps long-term operating current output within 150 A)

Regulated voltage precision

≤ ±1% (The output voltage is within 53.5 V DC ±0.1 V DCunder 50% loads.)

Peak-to-peak noise voltage

≤ 200 mV (rated input voltage and load)

Telephone noise weighting voltage

≤ 2 mV (300–3400 Hz, input power ≤ 264 V AC)

Current imbalance

≤ ±5% (50%–100% load)

AC input protection

AC input overvoltage protection threshold

≥ 300 V AC

AC input overvoltage recovery threshold

290 V AC to 300 V AC

AC input undervoltage protection threshold

≤80 V AC

AC input undervoltage recovery threshold

80 V AC to 90 V AC

DC output protection

DC output overvoltage protection threshold

–58.5 V DC to –60.5 V DC

Electromagnetic compatibility (EMC)

Conducted emission (CE)

AC port: EN 55022 class B

DC port: EN 55022 class A

Radiated emission (RE)

EN 55022 class B

Harmonic current

IEC 61000-3-12

Voltage fluctuation and flick

IEC 61000-3-3

Electrostatic discharge (ESD)

IEC 61000-4-2

Shell port: contact discharge of 6 kV and air discharge of 8 kV; signal port: contact discharge of 2 kV

Electrical fast transient (EFT)

IEC 61000-4-4

AC and DC power ports: 2 kV

Radiated susceptibility (RS)

IEC 61000-4-3

10 V/m field strength

Conducted susceptibility (CS)

IEC 61000-4-6

Power port: 10 V; signal port: 3 V

Surge immunity

IEC 61000-4-5

AC and DC power ports: 2 kV (8/20 µs) in differential mode, 4 kV (8/20 µs) in common mode

Voltage dips immunity (DIP)

IEC 61000-4-11

Others

Surge protection

AC power port: nominal lightning strike discharge current of 30 kA (8/20 µs), maximum lightning strike discharge current of 60 kA (8/20 µs)

DC power port: 10 kA (8/20 µs) in differential mode, 20 kA (8/20 µs) in common mode

Safety and regulatory design

IEC/EN60950-1 and GB4943, TUV and CE certifications

Mean time between failures (MTBF)

200,000 hours

Structure

Power system dimensions (H x W x D)

219.5 mm x 482.6 mm x 330 mm

Weight

≤ 20 kg (excluding rectifiers)

Protection level

IP20

Installation mode

Installed in a 19-inch rack

Cabling

Routed in and out from the top

Maintenance mode

Maintained from the front

Heat dissipation

Nature heat dissipation

Reviews

There are no reviews yet.

Be the first to review “ETP48200-C5B4”

Your email address will not be published. Required fields are marked *

Back to Top

Search For Products

Product has been added to your cart