The ETP48400-C3B5 is an embedded power system that converts AC power into DC power. It supplies –48 V and –57 V constant voltage to load equipment.

Description

Overview

 

The ETP48400-C3B5 is an embedded power system that converts AC power into DC power. It supplies –48 V and –57 V constant voltage to load equipment. The maximum capacity of the power system is 24 kW. It applies to newly built sites as well as capacity expansion and reconstruction scenarios of existing sites.

ETP48400-C3B5 Appearance

 

ETP48400-C3B5

(1) Label

(2) Ground screw

(3) Space for the AC input module

(4) Space for LLVD circuit breakers

(5) SMU02C

(6) Space for BLVD circuit breakers

(7) Battery wiring ports

(8) Space for the NIM01C3/CIM02C

(9) UIM05B1

(10) Installation positions and order of the R4850G2, R4850G5, and R4875G5

ETP48400-C3B5 Datasheet

Category

ETP48400-C3B5

Specifications

Environmental conditions

Operating temperature

–40°C to +65°C (When the ambient temperature is between –33°C and +55°C, the power system works properly. When the ambient temperature is greater than 55°C and less than or equal to 65°C, the output power is linearly derated to 80%. When the ambient temperature is –40°C, the power system can start properly after AC power is applied.)

Transportation temperature

–40°C to +70°C

Storage temperature

–40°C to +70°C

Operating humidity

5%–95% RH (non-condensing)

Storage humidity

5%–95% RH (non-condensing)

Altitude

0–4000 m

(When the altitude ranges from 2000 m to 4000 m, the temperature condition for high temperature derating decreases by 1°C for each additional 200 m.)

Noise

System audible noise: ≤ 60 dBA at 25°C, ≤ 72 dBA at 40°C; meets Class 3.1 requirements of ETSI 300753

Others

There is no conductive dust, corrosive gas, or explosion hazard.

Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with class 3.1 requirements in ETSI EN 300 019-1-3 (V2.3.2 or a later version).

AC input

Input frequency

45–66 Hz; rated value: 50 Hz/60 Hz

Power factor (PF)

≥ 0.99 (rated input voltage, 50%–100% load)

DC output

Output voltage

–53.5 V DC

Regulated voltage precision

≤ ±1%

Peak-to-peak noise voltage

≤ 200 mV (0–20 MHz)

Psophometrically weighted noise voltage

≤ 2 mV

Current sharing imbalance

≤ ±5% (50%–100% load)

AC input protection

AC input overvoltage protection threshold

≥ 300 V AC

AC input overvoltage recovery threshold

290–300 V AC

AC input undervoltage protection threshold

≤ 80 V AC

AC input undervoltage recovery threshold

80–90 V AC

DC output protection

DC output overvoltage protection threshold

–56 V DC to –60.5 V DC (default: 59.5 V DC)

EMC specifications

Conducted emission (CE)

  • AC port: EN 55032, Class B
  • DC port: EN 55032, Class A1
  • Signal port: EN 55032, Class B

Radiated emission (RE)

EN 55032, Class B

Harmonic current

IEC 61000-3-12

Voltage fluctuation and flicker

IEC 61000-3-11

Electrostatic discharge (ESD)

IEC 61000-4-2

Electrical fast transient (EFT)

IEC 61000-4-4

Radiated susceptibility (RS)

IEC 61000-4-3

Conducted susceptibility (CS)

IEC 61000-4-6

Surge susceptibility

IEC 61000-4-5

Voltage dip

IEC 61000-4-11

Others

MTBF

200,000 hours (at 25°C)

Structure

Power system (H x W x D)

130 mm x 482 mm x 330 mm

Weight

≤ 20 kg (excluding rectifiers)

IP rating

IP20

Installation mode

Installed in a 19-inch rack

Cabling

Routed in and out from the front

Maintenance mode

Maintained from the front

Cooling mode

Natural cooling

Additional information

Weight 12.0000 kg
Dimensions 58.0000 × 40.0000 × 17.0000 cm
Brand
Lead Time
Ship From
Warranty
Condition
ETP48400-C3B5 Datasheet

Category

ETP48400-C3B5

Specifications

Environmental conditions

Operating temperature

–40°C to +65°C (When the ambient temperature is between –33°C and +55°C, the power system works properly. When the ambient temperature is greater than 55°C and less than or equal to 65°C, the output power is linearly derated to 80%. When the ambient temperature is –40°C, the power system can start properly after AC power is applied.)

Transportation temperature

–40°C to +70°C

Storage temperature

–40°C to +70°C

Operating humidity

5%–95% RH (non-condensing)

Storage humidity

5%–95% RH (non-condensing)

Altitude

0–4000 m

(When the altitude ranges from 2000 m to 4000 m, the temperature condition for high temperature derating decreases by 1°C for each additional 200 m.)

Noise

System audible noise: ≤ 60 dBA at 25°C, ≤ 72 dBA at 40°C; meets Class 3.1 requirements of ETSI 300753

Others

There is no conductive dust, corrosive gas, or explosion hazard.

Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with class 3.1 requirements in ETSI EN 300 019-1-3 (V2.3.2 or a later version).

AC input

Input frequency

45–66 Hz; rated value: 50 Hz/60 Hz

Power factor (PF)

≥ 0.99 (rated input voltage, 50%–100% load)

DC output

Output voltage

–53.5 V DC

Regulated voltage precision

≤ ±1%

Peak-to-peak noise voltage

≤ 200 mV (0–20 MHz)

Psophometrically weighted noise voltage

≤ 2 mV

Current sharing imbalance

≤ ±5% (50%–100% load)

AC input protection

AC input overvoltage protection threshold

≥ 300 V AC

AC input overvoltage recovery threshold

290–300 V AC

AC input undervoltage protection threshold

≤ 80 V AC

AC input undervoltage recovery threshold

80–90 V AC

DC output protection

DC output overvoltage protection threshold

–56 V DC to –60.5 V DC (default: 59.5 V DC)

EMC specifications

Conducted emission (CE)

  • AC port: EN 55032, Class B
  • DC port: EN 55032, Class A1
  • Signal port: EN 55032, Class B

Radiated emission (RE)

EN 55032, Class B

Harmonic current

IEC 61000-3-12

Voltage fluctuation and flicker

IEC 61000-3-11

Electrostatic discharge (ESD)

IEC 61000-4-2

Electrical fast transient (EFT)

IEC 61000-4-4

Radiated susceptibility (RS)

IEC 61000-4-3

Conducted susceptibility (CS)

IEC 61000-4-6

Surge susceptibility

IEC 61000-4-5

Voltage dip

IEC 61000-4-11

Others

MTBF

200,000 hours (at 25°C)

Structure

Power system (H x W x D)

130 mm x 482 mm x 330 mm

Weight

≤ 20 kg (excluding rectifiers)

IP rating

IP20

Installation mode

Installed in a 19-inch rack

Cabling

Routed in and out from the front

Maintenance mode

Maintained from the front

Cooling mode

Natural cooling

Reviews

There are no reviews yet.

Be the first to review “ETP48400-C3B5”

Your email address will not be published. Required fields are marked *

Back to Top

Search For Products

Product has been added to your cart