NE40E-X16A DC

NE40E-X16A DC

NE40E-X16A Integrated DC Chassis Components (Including 4 Fan Tray)

SKU: 9453 PN: 2359914 Category:

Description

Item NE40E-X16A DC
Cabinet installation standard Can be installed in a standard 19″ 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
[2T bundle]Can be installed in a standard 19″ 1000 mm-deep cabinet,part number is 02115109(CR5B0N610E60)
Typical power consumption 7720 W (fully configured with LPUF-240s)
9040 W (fully configured with LPUF-480s)
12390 W (fully configured with LPUI-1Ts)
22450 W(fully configured with LPUI-2Ts)
Typical heat dissipation 25046.9 BTU/hour (fully configured with LPUF-240s)
29329.6 BTU/hour (fully configured with LPUF-480s)
40198.4 BTU/hour (fully configured with LPUI-1Ts)
72837.2 BTU/hour (fully configured with LPUI-2Ts)
DC input voltage input voltage range: –40 V to –72 V
input rated voltage: -48 V/–60 V
AC input voltage input voltage range: 180 V to 264 V
input rated voltage: 200 V to 240 V
HVDC input voltage input voltage range: 192 to 288V,264 to 400V
input rated voltage: 240 V/380 V
MTBF 22.33 years
MTTR 0.5 hours
Availability 0.999997444
Slot quantity 22
Redundant MPUs 0.042361111
Redundant Switch fabrics 3+1
Redundant fans [1T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
[2T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
Redundant power supply [1T bundle] DC: 9+1
[1T bundle] HVDC&AC: 7+1
[2T bundle] DC: 12+1
[2T bundle] HVDC&AC: 9+1
Forwarding performance 5600 Mpps (LPUF-240)
Switching capacity 50.32 Tbps (LPUI-1T)
81.92 Tbps (LPUI-2T)
Operating temperature Long-term: 0°C to 45°C (32°F to 113°F)
Short-term: –5°C to +55°C (23°F to131°F)
Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)
Storage temperature –40°C to +70°C (–40°F to +158°F)
Relative operating humidity Long term: 5% to 85% RH, non-condensing
Short term: 5% to 95% RH, non-condensing
Relative storage humidity 5% to 95% RH, non-condensing
Long-term operating altitude <= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
Storage altitude Less than 5000 m (16404 ft.)
Dimensions (H x W x D) (40 U) 1778 mm x 442 mm x 650 mm (70.00 in. x 17.40 in. x 25.59 in.) (Chassis main body)
(40 U) 1778 mm x 442 mm x 750 mm (70.00 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
[2T bundle](40 U) 1778 mm x 442 mm x 946 mm (70.00 in. x 17.40 in. x 37.24 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
Weight (empty) DC: 120.5 kg (265.7 lb) (without filler panels)
HVDC&AC: 111.7 kg (246.3 lb) (without filler panels)
Weight (full configuration) [1T bundle] DC:399.4 kg (880.68 lb)
[1T bundle] HVDC&AC:395.1 kg (871.2 lb)
[2T bundle] DC:461.3kg(1017.0 lb)
[2T bundle] HVDC&AC:453.3kg(999.34 lb)

Additional information

Weight 130.0000 kg
Dimensions 178.0000 × 45.0000 × 75.0000 cm

Reviews

There are no reviews yet.


Be the first to review “NE40E-X16A DC”

has been added to your cart:
Checkout