S12700E-12

Huawei S12700E-12 switch chassis with 12 LPU slots, 4 SFU slots, 2 MPU slots, 2 CMU slots, and 6 power module slots

Huawei

3-5 days

Shenzhen Warehouse

SKU: 2002444 PN: 2116009 Category: Tag:

Description

S12700E-12 Overview

Huawei CloudEngine S12700E series agile switches are core switches designed for next-generation campus networks.

  • Using a fully programmable switching architecture, the S12700E series switches allow for fast, flexible function customization and support a smooth evolution to software-defined networking (SDN).
  • The S12700E series switches provide the native wireless access controller (AC) capability to help build a wired and wireless converged network. Their unified user management capabilities deliver refined user and service management, and Huawei’s Packet Conservation Algorithm for Internet (iPCA) supports hop-by-hop monitoring of any service flows, helping you manage services in a more refined way.
  • The S12700E series switches run Huawei Versatile Routing Platform (VRP), which provides high-performance L2/L3 switching services as well as a variety of network services, such as MPLS VPN, desktop cloud, and video conferencing.
  • The S12700E series switches adopt next-generation switch fabric (NGSF), and use the cell switching technology to reduce the forwarding latency and improve the load balancing capability of switch fabric units (SFUs).
  • The S12700E series switches support single-link 100G hardware clustering and a variety of reliability technologies such as hardware Ethernet OAM, BFD, and ring network protection. These help you improve productivity and maximize network operation time, and therefore reduce the total cost of ownership (TCO).

The S12700E series switches come in three models: S12700E-4, S12700E-8, and S12700E-12. The maximum numbers of line processing units and switch fabric units supported by these models are:

  • S12700E-4: 2 MPUs, 2 SFUs, and 4 LPUs
  • S12700E-8: 2 MPUs, 4 SFUs, and 8 LPUs
  • S12700E-12: 2 MPUs, 4 SFUs and 12 LPUs

The S12700E-12 chassis provides 12 LPU slots, 4 SFU slots, 2 MPU slots, 2 CMU slots, and 6 power module slots.

 

Mapping between the S12700E-12 chassis and software versions
Chassis Version
S12700E-12 chassis Supported in V200R019C00 and later versions
Slot distribution in the S12700E-12 chassis

S12700E-12 8S12700E-12 10

Slot Type Slot ID Slot ID Remarks
MPU slots SLOT13, SLOT14 MPU MPUs in the two slots work in active/standby mode.
MPU slots SLOT15, SLOT18 SFU One to two SFUs can be installed.
MPU slots SLOT01 to SLOT014 NOTE:

The cards supported by a switch depend on the software version.

CMU slots CMU1, CMU2 CMU NOTE:

The cards supported by a switch depend on the software version.

CMU slots PWR1 to PWR6 Power Module
Fan module slot FAN1 to FAN5 Fan Module
Item S12700E-12
Switching capacity 57.6 Tbps/86.4 Tbps
Packet forwarding
rate
43200 Mpps
Service slots 12
Wireless network
management
Native AC.
Supports native N+N cold backup between ACs.
Supports cluster-based AC hot backup in cluster mode.
WLAN terminal location.
The function of locating interference sources is supported.
Supports the spectrum analysis function.
2.4G&5G load balancing, 5G priority mode is supported.
User management unified user management
802.1x, MAC address, and Portal authentication
Traffic-based and duration-based charging modes are supported.
Supports the grouping, domain-based, and time-based authorization.
iPCA quality awareness Service packets can be directly marked to obtain the number of lost packets and the packet loss ratio in real time.
Collects statistics on the number of lost packets and packet loss rate on Layer 2 and Layer 3 networks at the network and device levels.
SVF 2.0 virtualization A maximum of 4K client nodes (access switches and APs) can be virtualized into one device for management.
Supports Layer 2 ASs.
Supports hybrid networking management with third-party vendors.
VXLAN Distributed VXLAN gateway and centralized gateway
BGP-EVPN
VXLAN can be configured using NETCONF
MAC address Maximum number of MAC address entries, 512K
Automatic MAC address learning and aging
Supports static, dynamic, and blackhole MAC address entries.
Source MAC address filtering
MAC address learning limit based on port and VLAN
ARP 256K ARP entries
ARP Snooping
IP routing Specifications of IPv4 routing entries, 512K
Supports IPv4 dynamic routing protocols such as RIP, OSPF, ISIS, and BGP.
Supports IPv6 dynamic routing protocols such as RIPng, OSPFv3, ISISv6, and BGP4+.
Multicast Supports IGMP v1/v2/v3 and IGMPv1/v2/v3 snooping
Supports PIM-SM, PIM-DM, PIM-SSM
Supports 128, 000 multicast routing entries
Supports Multicast Source Discovery Protocol (MSDP) and Multiprotocol Extensions for BGP (MBGP)
Supports multicast traffic control
Supports multicast querier
Supports suppression on multicast packets
Supports multicast CAC, ACL
MPLS Supports basic MPLS functions
Supports MPLS OAM
Supports MPLS TE
Supports MPLS VPN/VLL/VPLS
Reliability Supports LACP and E-Trunk
Supports VRRP and BFD for VRRP
Supports BFD for BGP/IS-IS/OSPF/static route
Supports NSR, NSF, and GR for BGP/IS-IS/OSPF/LDP
Supports TE FRR and IP FRR
Supports Ethernet OAM (IEEE 802.3ah and 802.1ag) (Hardware-based)
Supports ITU-Y.1731
Supports DLDP
Supports Smartlink
Supports Monitor-link
Supports network management protocols such as SNMPv1/v2c/v3.
Supports terminal services such as console, Telnet, and SSH.
Supports the (Streaming Telemetry) technology for stream remote sensing.
QoS Supports combination traffic classification based on the Layer2 protocol header, Layer3 protocol, Layer4 protocol, and 802.1p priority.
Supports actions of ACL, CAR, re-mark, and schedule
Supports queue scheduling algorithms, such as SP, WRR, DRR, SP+WRR, and
SP+DRR
Supports congestion avoidance mechanisms, such as WRED and tail drop
Supports H-QoS
Supports traffic shaping
Configuration and maintenance Terminal access services such as console port login, Telnet, and SSH
Supports the network management protocols, such as SNMP v1/v2c/v3
Supports file uploading and downloading using FTP and TFTP
Supports BootROM upgrade and remote upgrade
Supports hot patches
Supports user operation logs
Supports eMDI
Security and management Supports MAC address, Portal, 802.1x and DHCP snooping triggered authentication
Supports MACsec
Supports RADIUS and HWTACACS authentication for login users
Supports command line authority control based on user levels, preventing unauthorized users from using commands configurations
Supports defense against DoS attacks, TCP SYN Flood attacks, UDP Flood attacks, broadcast storms, and heavy traffic attacks
Supports RMON.
Supports Secure Boot
Supports 1K CPU hardware queues to implement hierarchical scheduling and protection for protocol packets on the control plane.
Support for Big Data Security Collaboration
Value-added services Supports firewall
Supports NAT
Supports Intrusion Protection System
Supports IPSec, SSL VPN
Supports Cybersecurity Intelligence System
Supports Encrypted Communication Analytics
Supports Load balancing Analog Digital Conversion
Interoperability VLAN-based Spanning Tree (VBST) (interoperating with PVST, PVST+, and RPVST)
Link-type Negotiation Protocol (LNP) (similar to DTP)
VLAN Central Management Protocol (VCMP) (similar to VTP)
Energy saving Supports IEEE 802.3az: Energy Efficient Ethernet (EEE)
Dimensions(W x D x H) 841.75 mm × 442 mm × 517.4 mm
Chassis weight(empty) 71.8KG
Operating voltage DC: –48 V to –60 V
AC: 90 V to 290V
Power supply
capability of the equipment
8981W
Chassis Model Chassis Model
S12700E-4 Supports double Main Processing Units (MPUs), four Line Processing Units (LPUs), two Switch Fabric Units (SFUs), and AC or DC power modules in N+N/N+1/N+0 (no redundancy) backup mode.
S12700E-8 Supports double MPUs, eight LPUs, four SFUs, and AC or DC power modules in N+N/N+1/N+0 (no redundancy) backup mode.
S12700E-12 Supports double MPUs, twelve LPUs, four SFUs, and AC or DC power modules in N+N/N+1/N+0 (no redundancy) backup mode.

Reviews

There are no reviews yet.


Be the first to review “S12700E-12”