S12710

Huawei S12710 switch Bundle include 2 SPU slots, 2 MPU slots, 10 LPU slots, 4 Power Module slots, 2 Fan Module slots, supports both AC and DC power modules

Huawei

3-5 days

Shenzhen Warehouse

SKU: 11990 PN: 02350XYF Category: Tag:

Description

S12710 overview

HUAWEI S12700 series agile switches (S12700 for short) are designed for next-generation campus networks. Using a fully programmable switching architecture, the S12700 allows fast, flexible function customization and supports a smooth evolution to Software-Defined Networking (SDN). The S12700 uses a Huawei Ethernet Network Processor (ENP) and provides a native Wireless Access Controller (AC) to help build a wired and wireless converged network. Its Unified User Management capabilities deliver unified user and service management, and Huawei’s Packet Conservation Algorithm for Internet (iPCA) supports hop-by-hop monitoring of any service flows, helping manage services in a more refined way.
The S12700 runs the Huawei Versatile Routing Platform (VRP), which provides high-performance L2/L3 switching services and rich network services, such as Multiprotocol Label Switching (MPLS) VPN, hardware IPv6, desktop cloud, and video conferencing. In addition, the S12700 series uses a variety of reliability technologies, including non-stop forwarding, hardware Eth-OAM/BFD, ring network protection, and Cluster Switch System Generation2 (CSS2) — a switch fabric hardware clustering technology that allows 1+N backup of Main Processing Units (MPUs). These technologies help improve productivity and maximize network operation time, reducing Total Cost of Ownership (TCO).

 

S12710 appearance and structure

The S12710 chassis is 15 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 663.9 mm x 442 mm x 585 mm.

S12710 chassis structure (front view):

 

S12710 chassis structure (front view)

1. Ten LPUs, including:

2. Two MPUs 3. A pair of mounting brackets

NOTE:

The mounting brackets are used to secure the chassis in the cabinet.

4. Four power modules 5. Two CMUs 6. Front ESD jack

NOTE:

The ground terminal of an ESD wrist strap can be inserted into this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.

7. Cable management frames

NOTE:

Cable management frames are used to route cables.

8. Two Switch Fabric Units
Item S12710
Number of LPU slots  10
Number of MPU slots  2
Number of SFU slots  2
Number of fan slots  4
Number of power module slots  4
Maximum port density
  • V200R010C00 and V200R011C10: 480xFE, 480xGE, 480x10GE, 80x40GE, 40x100GE
  • V200R012C00 and later versions: 480xFE, 480xGE, 480x10GE, 160x40GE, 80x100GE
 Installation In an N66E or N68E cabinet, one cabinet for one chassis
 Cluster switch system (CSS) Supports CSS card clustering (CSS cards integrated on main control unit and SFU, with fixed CSS ports on panels)
Maximum power consumption (fully configured)

NOTE:

The heat dissipation value of a chassis equals the current power consumption of the chassis.

4644 W
Power specifications
  • DC input voltage

    Rated voltage: -48 V DC to -60 V DC

    Maximum voltage range: -40 V DC to -72 V DC

  • AC input voltage

    Rated voltage: 110 V AC/220 V AC, 50/60 Hz

    Maximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The maximum output power reduces by a half when the input voltage ranges from 90 V AC to 175 V AC.)

  • HVDC input voltage (3000 W AC)

    Rated voltage: 240 V DC

    Maximum voltage range: 190 V DC to 290 V DC

Dimensions (H x W x D, without rack-mounting brackets)
  • With cable management frames (15 U high): 663.9 mm x 442 mm x 585 mm (26.1 in. x 17.4 in. x 23.0 in.)
  • Without cable management frames (15 U high): 663.9 mm x 442 mm x 517.4 mm (26.1 in. x 17.4 in. x 20.37 in.)
Weight (empty/fully configured) 28.6 kg/98.4 kg (63.05 lb/216.93 lb)
Reliability and availability
  • Mean Time Between Failures (MTBF): 40.04 years
  • Mean time to repair (MTTR): 2 hours
  • Availability: 0.9999984

NOTE:

The preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules installed on the product.

Environment specifications
  • Operating temperature and altitude:

    -60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)

    1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.).

    4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)

  • Relative humidity: 5% RH to 95% RH (noncondensing)
  • Storage temperature: -40°C to +70°C (-40°F to +158°F)
  • Storage altitude: < 5000 m (16404 ft.)
Noise under normal temperature (sound power) ≤ 75.7 dB(A)
Certification
  • EMC certification
  • Safety certification
  • Manufacturing certification
Part number 02114860
Chassis Model Description
S12704 Supports double Main Processing Units (MPUs), four Line Processing Units (LPUs), two Switch Fabric Units (SFUs), and AC or DC power modules in N+N/N+1/N+0 (no redundancy) backup mode.
S12708 Supports double MPUs, eight LPUs, four SFUs, and AC or DC power modules in N+N/N+1/N+0 (no redundancy) backup mode.
S12710 Supports double MPUs, ten LPUs, two SFUs, and AC or DC power modules in N+N/N+1/N+0 (no redundancy) backup mode.
S12712 Supports double MPUs, twelve LPUs, four SFUs, and AC or DC power modules in N+N/N+1/N+0 (no redundancy) backup mode.

Reviews

There are no reviews yet.


Be the first to review “S12710”

has been added to your cart:
Checkout