S5731-S48S4X
Huawei S5731-S48S4X switch supports 48 GE SFP ports, 4 10GE SFP+ ports, without power module
Shenzhen Warehouse
3-5 days
Huawei
- Description
- DATASHEET
- Download
- Reviews (0)
Description
S5731-S48S4X overview
This Huawei switch supports 48*GE SFP ports, 4*10GE SFP+ ports, without power module
The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch. However, the power modules with natural heat dissipation and the power modules with fan cannot be used at the same time.
The has three built-in fans for forced air cooling. Air flows in from the left, right, and front sides, and exhausts from the rear panel.
S5731-S48S4X quick spec
48*GE SFP ports
4*10GE SFP+ ports
without power module
S5731-S48S4X appearance and structure
1 | Forty-eight 100/1000BASE-X ports |
2 | Four 10GE SFP+ ports |
3 | One console port |
4 | One ETH management port |
5 | One PNP button |
6 | Ground screw |
Item | S5731-S48S4X |
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz |
High-voltage DC input: 240 V DC | |
Input voltage range [V] | AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz |
High-voltage DC input: 190 V DC to 290 V DC | |
DC input: –38.4 V DC to –72 V DC | |
Maximum input current [A] | The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications. |
Memory | 2 GB |
Flash memory | The physical space is 1 GB. You can run the display version command to view the actual available space. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Not supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | – |
Power supply surge protection [kV] | Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode |
Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode | |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from left,front and right, air exhaustion from behind |
PoE | Not supported |
Certification | EMC certification |
Safety certification | |
Manufacturing certification | |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 448.0 mm (1.72 in. x 17.40 in. x 17.64 in.) | |
Dimensions with packaging (H x W x D) [mm(in.)] | 185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 5.12 kg (11.29 lb) |
Weight with packaging [kg(lb)] | 7.65 kg (16.87 lb) |
Typical power consumption [W] | 93.69 W |
Typical heat dissipation [BTU/hour] | 319.68 BTU/hour |
Maximum power consumption [W] | 128.89 (150 W AC or 180 W DC) |
141.96 (600 W AC) | |
Maximum heat dissipation [BTU/hour] | 439.79 (150 W AC or 180 W DC) |
484.38 (600 W AC) | |
MTBF [year] | 64.97 year |
MTtr [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | 45.47 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 31.79 dB(A) |
Number of card slots | 0 |
Number of power slots | 2 |
Number of fans modules | 3 |
Redundant power supply | 1+1 |
Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together. | |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met: | |
The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year. | |
The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours. | |
The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year. | |
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. | |
Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. | |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Reviews
There are no reviews yet.