My Cart

Mini Cart

CATEGORIES
My Cart

Mini Cart

S5732-H24S6Q-AC

PN 02353AJS

Huawei S5732-H24S6Q-AC switch supports 20 GE SFP ports, 4 10GE SFP+ ports, 6 40 GE QSFP+ ports, 2 hot swappable AC/DC power supplies, 1 AC power module equipped

Shenzhen Warehouse
lead time 3-5 days
- +
Overview
S5732-H24S6Q-AC Overview

 

Huawei S5732-H24S6Q-AC with 20 GE SFP ports, 4 10GE SFP+ ports, 6 40GE QSFP+ ports. 

The Huawei CloudEngine S5732-H series switches are the next-generation enhanced all-optical Ethernet switches developed by Huawei. The CloudEngine S5732-H builds on Huawei's unified Versatile Routing Platform (VRP) and boasts various IDN features.

Telecomate.com provides a full range of Huawei switch series, if you have any demands, please contact: csd@telecomate.com

 

S5732-H24S6Q-AC Quick Spec

 

20 GE SFP ports, 4 10GE SFP+ ports, 6 40GE QSFP+ ports

Forwarding performance is 450/522 MPPS

Switching capacity is 2.4Tbps/24 Tbps

 

S5732-H24S6Q-AC appearance and structure

 S5732-H24S6Q-AC

1

Twenty 1000BASE-X ports

9

One PNP button

2

Four 10GE SFP+ ports

10

Fan module slot 1

3

Six 40GE QSFP+ optical ports

11

Fan module slot 2

4

Ground screw 

12

Fan module slot 3

5

SSD card slot

13

Fan module slot 4

6

One ETH management port

14

Power module slot 1

7

One USB port

15

Power module slot 1

 

Datasheet
S5732-H24S6Q-AC Datasheet

 

Item

S5732-H24S6Q-AC

Forwarding Performance

450 MPPS

Switching Capacity

600 Gbit/s/2.4 Tbit/s

Fixed ports

20 x GE SFP ports, 4 x 10 GE SFP+ ports, 6 x 40 GE QSFP+ ports

Power supply type

600 W AC (pluggable)
1000 W DC (pluggable)

Rated voltage range

AC input (600 W AC ): 100 V AC to 240 V
AC, 50/60 Hz
DC input (1000 W DC): -48 VDC to -60 V DC

Maximum voltage
range

AC input (600 W AC ): 90 V AC to 290 V AC,
45 Hz to 65 Hz
High-voltage DC input (600 W AC): 190 V
DC to 290 V DC (meeting 240 V high-voltage
DC certification)
DC input (1000 W DC): -36 V DC to -72V DC

Maximum power
consumption

229 W

Noise

Under normal temperature (sound power):
65dB (A)
Under high temperature (sound power):
88dB (A)
Under normal temperature (sound pressure):
52dB (A)

Operating
temperature

 

0-1800 m altitude: -5°C to +45°C
1800-5000 m altitude: The operating
temperature reduces by 1ºC every time the
altitude increases by 220 m.

Operating temperature

0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) 

Storage temperature

-40℃ to +70℃

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Relative humidity

5% to 95% (non-condensing)

Surge protection
specification (power
port)

AC power port: ±6 kV in differential mode, ±6
kV in common mode
DC power port: ±2 kV in differential mode, ±4
kV in common mode

Heat dissipation

Air cooling heat dissipation, intelligent speed
adjustment, and pluggable fans

MAC address
table

IEEE 802.1d standards compliance

128K MAC address entries

MAC address learning and aging

Static, dynamic, and blackhole MAC address entries

Packet filtering based on source MAC addresses

VLAN

4094 VLANs
Guest VLAN and voice VLAN
GVRP
MUX VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
VLAN mapping

Wireless service

AP access control, AP domain management, and AP configuration template management
Radio management, unified static configuration, and dynamic centralized management
WLAN basic services, QoS, security, and user management
CAPWAP, tag/terminal location, and spectrum analysis

Ethernet loop
protection

RRPP ring topology and RRPP multi-instance
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switching
SEP
ERPS (G.8032)
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
BPDU protection, root protection, and loop protection

MPLS

MPLS L3VPN
MPLS L2VPN (VPWS/VPLS)
MPLS-TE
MPLS QoS

IP routing

Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy
Up to 192K FIBv4 entries
Up to 80K FIBv6 entries

Interoperability

VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST
Link-type Negotiation Protocol (LNP), similar to DTP
VLAN Central Management Protocol (VCMP), similar to VTP

IPv6 features

Up to 80K ND entries
PMTU
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet
ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types
Multicast Listener Discovery snooping (MLDv1/v2)
IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN

Multicast

IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast forwarding in a VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics
IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM
MSDP
MVPN

QoS/ACL

Rate limiting in the inbound and outbound directions of a port
Packet redirection
Port-based traffic policing and two-rate three-color CAR
Eight queues per port
DRR, SP and DRR+SP queue scheduling algorithms
WRED
Re-marking of the 802.1p and DSCP fields of packets
Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address,
destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol
type, and VLAN ID
Queue-based rate limiting and shaping on ports

Security

Hierarchical user management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, port number, and VLAN ID
Port isolation, port security, and sticky MAC
MAC Forced Forwarding (MFF)
Blackhole MAC address entries
Limit on the number of learned MAC addresses
IEEE 802.1x authentication and limit on the number of users on a port
AAA authentication, RADIUS authentication, and HWTACACS authentication
NAC

SSH V2.0
HTTPS
CPU protection
Blacklist and whitelist
Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets
Secure Boot
IPSec
ECA
Deception

Reliability

LACP
E-trunk
Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag)
ITU-Y.1731
DLDP
LLDP
BFD for BGP, BFD for IS-IS, BFD for OSPF, BFD for static route

VXLAN*

VXLAN L2 and L3 gateways
Centralized and distributed gateway
BGP-EVPN
Configured through the NETCONF protocol

Super Virtual
Fabric (SVF)

Working as an SVF Parent to vertically virtualize downlink switches and APs as one device for
management.
A two-layer client architecture is supported.
IGMP snooping can be enabled on access switches (ASs) and the maximum number of access users on
a port can be configured.
ASs can be independently configured. Services that are not supported by templates can be configured on
the parent.
Third-party devices are allowed between SVF parent and clients.

iPCA

Directly coloring service packets to collect real-time statistics on the number of lost packets and packet
loss ratio
Collection of statistics on the number of lost packets and packet loss ratio at network and device levels

TWAMP

Two-way IP link performance measurement
Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter

Management
and
maintenance

iStack, with up to 9 member switches in a stack
SNMP v1/v2c/v3
RMON

Smart Application Control (SAC)
Web-based NMS
System logs and alarms of different levels
GVRP
MUX VLAN
NetStream
Intelligent O&M

Dimensions (W x D x
H)

442 mm x 420 mm x 43.6 mm

 

Related Products

Reviews 1
  1. Mexico
    100%
    QSFP+ optical port is a 40GE port. In V200R020C00 and later versions, a license can be loaded to increase the port rate to 100 Gbit/s. So i bought a 100G license from Telecomate.com.

Write Your Own Review

You're reviewing: S5732-H24S6Q-AC

DELIVERY & RETURN

Custom static block for product detail
 
FAST DELIVERY

5-7 days global delivery

 
100% QUALITY ASSURED

2-times test procedure

 
Trusted Store

5 Years trusted online store

 
Money back & Return

RMA & Return to guarantee your money back