S5736-S24S4XC

S5736-S24S4XC

Huawei S5736-S24S4XC switch supports 24 GE SFP ports, 4 10GE SFP+ ports, 1 expansion slot,1+1 power supply backup

Huawei

3-5 days

Shenzhen Warehouse

SKU: 2006658 PN: 98011038 Category: Tags: , ,

Description

S5736-S24S4XC overview

This Huawei switch comes with 24 GE SFP ports, 4 10GE SFP+ ports, 1 expansion slot, is one of the Cloud Engine Huawei S5736-S series switches.

Huawei Cloud Engine S5736-S series switches are next-generation standard all-optical GE access switches that provide 24-port and 48-port models and provide four 10GE ports and one extended slot(optional)

Huawei Cloud Engine S5736-S series all-optical GE access switches are developed based on next-generation high-performing hardware and the Huawei Versatile Routing Platform (VRP), support enhanced Layer 3 features simplified operations and maintenance (O&M), flexible Ethernet networking, and mature IPv6 features. Cloud Engine S5736-S switches can be used in various scenarios. For example, it can be used as an access or aggregation switch on a campus network or as an access switch for Metropolitan Area Network.

 

S5736-S24S4XC fast spec

24 x GE SFP ports, 4 x 10 GE SFP+ ports
One extended slot
1+1 power supply backup
Forwarding performance: 240 Mpps
Switching capacity: 448 Gbps/1.36 Tbps

 

S5736-S24S4XC basic information

 

1 Twenty-four 100/1000BASE-X ports.

eSFP-GE-SX-MM850 eSFP-GE-ZX100-SM1550 LE2MGSC40DE0

2 Four 10GE SFP+ optical ports

OMXD30000 OSX010000 OSX040N01 SFP-10G-ZR SFP-10G-USR

3 One console port
4 One ETH management port
5 One USB port
6 One PNP button
7 Ground screw
8 Rear card slot
9 Fan module slot 1
10 Fan module slot 2
11 Power module slot 1
12 Power module slot 2
Item S5736-S24S4XC
Memory 2 GB
Flash memory 1 GB in total. To view the available flash memory size, run the display version command.
Console port RJ45
Eth Management port RJ45
USB Supported
RTC Supported
RPS input Not supported
Power supply surge protection [kV] Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
Types of fans Pluggable
Heat dissipation mode Heat dissipation with fan, intelligent fan speed adjustment
Airflow direction Air intake from left,front and right, air exhaustion from behind
PoE Not supported
Certification EMC certification
Safety certification
Manufacturing certification
Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 444.0 mm (1.72 in. x 17.40 in. x 17.48 in.)
Dimensions with packaging (H x W x D) [mm(in.)] 150mm × 710mm × 560mm (5.90 in. x 27.95 in. x 22.05 in.)
Chassis height [U] 1 U
Weight without packaging [kg(lb)] 5.2 kg (11.46 lb)
Weight with packaging [kg(lb)] 8.2 kg (18.08 lb)
Typical power consumption [W] 63 W
Typical heat dissipation [BTU/hour] 214.96 BTU/hour
Maximum power consumption [W] 74 W
Maximum heat dissipation [BTU/hour] 252.5 BTU/hour
MTBF [year] 65.79 year
MTtr [hour] 2 hour
Availability >0.99999
Noise at normal temperature (acoustic power) [dB(A)] 49.9 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 37.8 dB(A)
Number of card slots 1
Number of power slots 2
Number of fans modules 2
Redundant power supply 1+1
Pluggable AC and DC power modules can be used together in the same switch, but power modules that use natural heat dissipation and power modules that use air cooling cannot be used together.
Long-term operating temperature [°C(°F)] -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Short-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year.
The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.
The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year.
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur.
Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km.
Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Long-term operating relative humidity [RH] 5% to 95%, noncondensing
Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Power supply mode Pluggable power supply
Rated input voltage [V] AC input: 100 V AC to 240 V AC, 50/60 Hz
DC input: –48 V DC to –60 V DC
Input voltage range [V] AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz
High-voltage DC input: 190 V DC to 290 V DC
DC input: –38.4 V DC to –72 V DC
Maximum input current [A] The current specifications depend on the pluggable power modules in use. For details, see the related power module specifications.

1 review for S5736-S24S4XC

  1. 5 out of 5

    Adriano

    The sales representative recommended compatible modules to me, which are cheaper than the original Huawei products. We tested it with an optical power meter, and the results were all within the normal range.


Add a review

has been added to your cart:
Checkout