SSQ2CXL111

Huawei OSN1500 OSN2500 STM-1 155M SCC unit, Clock and Line units, Integrated Cross-connect Board, STM-1 155M line board with 1 L-1.1 40km SFP module

SKU: 4386 PN: 03055407 Category:

Description

SSQ2CXL111 Version Description

 

The CXL1 is available in several functional versions. The functions provided by the functional versions are different.

Item Description
Functional versions The CXL1 is available in two functional versions, namely, Q2 and Q3. The Q3CXL1 is discontinued.
Differences
  • Interface specifications: receipt of NE ID check results.
  • Maintenance features: CF cards.
  • DCC processing capability.
  • Others: transparent transmission of DCC overhead information over external clock interfaces.
Substitution The Q5CXLLN can substitute for the Q2CXL1 that operates at the same line rate by using the board version replacement function, but active and standby boards must be the same, Q5CXLLN boards or Q2CXL1 boards.

 

SSQ2CXL111 Application

 

The CXL1 provides service processing, service grooming, clock input/output, and communication control functions in the OptiX OSN system.

The CXL provides the other boards in the system with the timing information, processes the SDH signals, grooms the services between line boards or tributary boards, communicates with the other boards in the system, and performs the configuration and management functions for the other boards in the system.

 

SSQ2CXL111 Functions and Features

 

The CXL1 processes SDH signals, controls communication, grooms services, and inputs/outputs clock signals.

SDH Processing Unit

Function and Feature CXL1
Basic functions Transmits and receives 1xSTM-1 optical signals.
Specifications of the optical interface
  • Supports different types of standard optical interfaces, namely, the I-1, S-1.1, L-1.1, L-1.2, and Ve-1.2.
  • The characteristics of the optical interfaces of the I-1, S-1.1, L-1.1, and L-1.2 types comply with ITU-T G.957.
  • The characteristics of the optical interface of the Ve-1.2 type comply with the standards defined by Huawei.
Specifications of the optical module
  • Supports the detection and query of the information about the optical module.
  • Supports the usage and detection of the SFP optical module, which facilitates the maintenance and upgrading of the optical module.
  • Provides the ALS function. The optical interface supports the setting of the on/off state of a laser.
Service processing Supports the VC-12 services, VC-3 services, and VC-4 services.
Overhead processing
  • Processes the section overheads of the STM-1 signals.
  • Supports the transparent transmission and termination of the path overheads.
  • Supports the setting and query of the J0, J1, and C2 bytes.
  • Supports one channel of ECC communication.
Alarms and performance events Reports various alarms and performance events, which facilitates the management and maintenance of the equipment.
Protection schemes Supports the following protection schemes:

  • Two-fiber ring MSP
  • Four-fiber ring MSP
  • Linear MSP
  • SNCP
  • SNCMP
  • SNCTP
  • Fiber-Shared Virtual Trail Protection
Maintenance features
  • Supports inloops and outloops at optical interfaces.
  • Supports warm resets and cold resets. The warm reset does not affect services.
  • Supports the query of the manufacturing information of the board.
  • Supports the in-service loading of the FPGA.
  • Supports the upgrade of the board software without affecting services.

 

SCC Unit

 

Function and Feature CXL1
Basic functions Configures and monitors services, monitors the service performance, and collects the information about the performance events and alarms.
Specifications of the interfaces
  • Provides one 10M/100M compatible Ethernet NM interface, which is accessed through the AUX.
  • Provides the RS232 OAM interface, which is accessed through the AUX and is used for connecting a PC or workstation. Supports the remote maintenance by using the RS232 DCE modem.
  • Provides one orderwire interface, which is accessed through the EOW.
  • Provides four broadcast data ports (serial1-4), which are accessed through the EOW.
Maintenance features The Q3CXL1 supports the CF card, simulation package loading, and diffused loading. The CF card is hot swappable. The capacity of a standard CF card is 512 MB and can be expanded to 1 GB.
DCC processing capability Supports channel types of D1-D1, D1-D3, and D4-D12. For details, see OAM Information Interworking.
Fan alarm management Manages fan alarms.
PIU management Supports the in-service check function for the PIU and supports the failure check function for the lightning protection module of the PIU.
Protection schemes Supports the 1+1 Hot Backup for the Cross-Connect, Timing and SCC Units.

 

Cross-Connect Unit

 

Function and Feature CXL1
Basic functions
  • Higher order cross-connect capacity: 20 Gbit/s
  • Lower order cross-connect capacity: 20 Gbit/s
  • Access capacity: 15 Gbit/s
Fast emergency channel Provides two 4 Mbit/s HDLC fast emergency channels, which are used for the MSP switching, SNCP switching, TPS, or other functions.
Service processing
  • Dynamically grooms services.
  • Adds or deletes services without interrupting other services.
  • Supports the SNCP protection at the VC-4, VC-3 and VC-12 levels.
  • Supports a maximum of 12 linear MSP protection groups.
  • Supports a maximum of 9 ring MSP protection groups.
  • Q2CXL1: in V100R010C02/V100R010C03 versions, supports a maximum of 2016 SNCP groups; in V100R010C00/V100R010C01 versions, supports a maximum of 1184 SNCP groups.
  • Q3CXL1: Supports a maximum of 1184 SNCP protection groups.
  • Supports a maximum of 592 SNCMP protection groups.
  • Supports a maximum of 512 SNCTP protection groups.
Protection schemes Supports the 1+1 Hot Backup for the Cross-Connect, Timing and SCC Units (non-revertive, by default).
Clock Unit
Function and Feature CXL1
Basic functions Provides the standard system synchronization clock.
Other functions
  • Supports the extraction, insertion, and management of the SSM and clock ID.
  • The Q3CXL1 supports the transmission of the DCC overhead information at two external clock interfaces.
Input and output
  • Inputs two-channel 2048 kHz or 2048 kbit/s timing signals and selects the external timing source.
  • Outputs two-channel 2048 Hz or 2048 kbit/s timing signals.

 

SSQ2CXL111 Valid Slots

 

The CXL1 must be installed in a valid slot in the subrack. Otherwise, the CXL1 cannot work normally.

The CXL1 can be installed in slots 4 and 5 in the subrack.

By default, slot 4 houses the active board and slot 5 houses the standby board

 

SSQ2CXL111 Feature Code

 

The number code that follows the board name in the bar code is the feature code of the board. The feature code of the CXL1 indicates the type of optical interface.

Board Feature Code Type of Optical Interface
SSQ3CXL110 and SSQ2CXL110 10 S-1.1
SSQ3CXL111 and SSQ2CXL111 11 L-1.1
SSQ3CXL112 and SSQ2CXL112 12 L-1.2
SSQ3CXL113 and SSQ2CXL113 13 Ve-1.2
SSQ3CXL114 and SSQ2CXL114 14 I-1

 

SSQ2CXL111 Technical Specifications

 

The technical specifications of the CXL1 include the parameters specified for optical interfaces, laser safety class, mechanical specifications, and power consumption.

Parameters Specified for Optical Interfaces

 

Parameter Value
Nominal bit rate 155520 kbit/s
Line code pattern NRZ
Application code I-1 S-1.1 L-1.1 L-1.2 Ve-1.2
Transmission distance (km) 0 to 2 2 to 15 15 to 40 40 to 80 80 to 100
Operating wavelength range (nm) 1260 to 1360 1261 to 1360 1263 to 1360 1480 to 1580 1480 to 1580
Type of fiber Single-mode LC Single-mode LC Single-mode LC Single-mode LC Single-mode LC
Mean launched optical power (dBm) -15 to -8 -15 to -8 -5 to 0 -5 to 0 -3 to 0
Receiver sensitivity (dBm) -23 -28 -34 -34 -34
Minimum overload (dBm) -8 -8 -10 -10 -10
Minimum extinction ratio (dB) 8.2 8.2 10 10 10
Maximum -20 dB spectral width (nm) 1 1
Minimum side mode suppression ratio (dB) 30 30

 

Laser Safety Class

 

The safety class of the laser on the board is Class 1. The maximum launched optical power of the optical interfaces is less than 10 dBm (10 mW).

 

Mechanical Specifications

 

The mechanical specifications of the CXL1 are as follows:

  • Dimensions (mm): 25.4 (W) x 235.2 (D) x 261.4 (H)
  • Weight of the Q2CXL1 (kg): 1.1
  • Weight of the Q3CXL1 (kg): 1.1

Power Consumption

The maximum power consumption of the CXL1 at room temperature (25°C) is 40 W.

Optical Interface Parameter
Parameter Value
Nominal bit rate 155520 kbit/s
Line code pattern NRZ
Application code L-1.1
Transmission distance (km) 15 to 40
Type of fiber Single-mode LC
Operating wavelength range (nm) 1263 to 1360
Launched optical power range (dBm) -15 to 0
Receiver sensitivity (dBm) -34
Minimum overload (dBm) -10
Minimum extinction ratio (dB) 10
Maximum -20 dB spectral width (nm)
Minimum side mode suppression ratio (dB)
Mechanical Speifications
Dimensions (mm) 25.4 (W) x 220 (D) x 262.05 (H)
Weight (kg) 1.1

Additional information

Weight 3.0000 kg
Dimensions 37.5000 × 34.0000 × 7.5000 cm

Reviews

There are no reviews yet.


Be the first to review “SSQ2CXL111”