Issue Description
The S6730-24X6C switch is giving a license warning message
“Warning: Current license state is Trial. xx days remain!”
Alarm Information
After checking the switch diagnose
– License feature All is near the deadline, remaining time is xx days alarm found
![]()
– “The ESN of the card does not match the license file.” alarm found
![]()
Handling Process
-Need to check ESN on the switch:
display esn

display elabel

– Need to check License activation file details
>>ESN in license file :

Root Cause
– License is activated for only one ESN (one slot) not for all slots
Solution
– To activate the license with all ESNs on the switch
Note: each ESN must be followed by a comma “,” on the ESDP system
1-

2)

3)

Suggestions
-Once ESN change application is approved, New license activation file can be downloaded and activated

Leave a comment