ETP48200-C4A3

0 Reviews Write a review
SKU2034504
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

Huawei ETP48200-C4A3 embedded telecom power system that supplies power to –48 V DC communications equipment with a maximum current of 86 A.

Description

Overview

ETP48200-C4A3 is an embedded telecom power system that supplies power to –48 V DC communications equipment with a maximum current of 86 A.

 

ETP48200-C4A3 Appearance

ETP48200 C4A3 PIC

 

(1) SMU02B

(2) AC input circuit breaker

(3) AC input terminals (behind the cover)

(4) Ground terminal (behind the cover)

(5) Load fuse holder

(6) Negative wiring bar for DC output

(7) RTN+ busbar

(8) UIM02C

(9) Battery circuit breaker

(10) Battery wiring terminals (behind the cover)

(11) Fuse extracting unit

(12) Space for rectifiers

 

 

System Configurations

Item

ETP48200-C4A3

Application environment

Indoor Class B

Subrack

  • 1 U rectifier space
  • 1 U monitoring unit
  • 2 U space for power distribution components

PDU

  • AC power distribution: AC input terminals
  • DC power distribution: battery low voltage disconnection (BLVD) route, load low voltage disconnection (LLVD) route, and battery route

Monitoring unit

SMU02B

UIM

UIM02C

Rectifier

A maximum of four R4850G2s

Item ETP48200-C4A3

Environment

Operating temperature

–20°C to +55°C

Transportation temperature

–40°C to +70°C

Storage temperature

–40°C to +70°C

Operating humidity

5%–95% RH (non-condensing)

Storage humidity

5%–95% RH (non-condensing)

Altitude

0–4000 m

When the altitude ranges from 2000 m to 4000 m, the operating temperature decreases by 1°C for each additional 200 m.

AC input

Input system

100/200 V AC single-phase, three wires (U, N, and V)

Input frequency

45–66 Hz (rated frequency: 50 Hz or 60 Hz)

Power factor (PF)

≥ 0.99 (rated input, with loads)

Total harmonic distortion (THD)

≤ 10% (configured with 50%–100% loads; Ta=25°C; 50 Hz or 60 Hz)

DC output

Output voltage range

–42 V DC to –58 V DC

Default output voltage

–56 V DC

Output power

When the module input voltage is 100 V AC, the maximum system output current is 86 A 53.5 V and a maximum of 80 A load is supported.

Regulated voltage precision

≤ ±1% (The output voltage is within –53.5 V DC ±0.1 under 50% loads.)

Peak-to-peak noise voltage

≤ 200 mV (within the range of rated input voltage and loads)

Psophometrically weighted noise

≤ 2 mV (300–3400 Hz, input power ≤ 264 V AC)

Current imbalance

≤ ±5% (50%–100% loads)

AC input protection

AC input overvoltage alarm threshold

≥ 120 V AC

AC input overvoltage recovery threshold

110–120 V AC

AC input undervoltage protection threshold

≤ 80 V AC

AC input undervoltage recovery threshold

80–90 V AC

DC output protection

DC output overvoltage protection threshold

–58.5 V DC to –60.5 V DC

Failure rate

Rectifier

  • The annual failure rate is about 1% for use in the type B environment.
  • When it is installed in the IP55 natural-ventilation cabinet, the annual failure rate is about 2% in the type C or D environment.

SMU

0.5%

UIM

0.5%

Battery

1%

Electromagnetic compatibility (EMC) specifications

Conducted emission (CE)

Input port: Class B of CISPR 22/EN 55022

Output port: Class A of CISPR 22/EN 55022

Radiated interference

Class B of CISPR 22/EN 55022

Harmonic current

IEC 61000-3-12

Voltage fluctuation and flick

IEC 61000-3-3

Electrostatic discharge (ESD)

IEC61000-4-2

Shell ports: contact discharge of 6 kV and air discharge of 8 kV; signal ports: contact discharge of 2 kV (criterion B)

Electrical fast transient (EFT)

IEC61000-4-4

Signal port: 1 kV; power port: 2 kV (criterion B)

Radiated susceptibility (RS)

IEC61000-4-3

Field strength of 10 V/m (criterion A)

Conducted susceptibility (CS)

IEC61000-4-6

Power port: 10 V; signal port: 3 V (criterion A)

Surge immunity

IEC61000-4-5

For AC and DC power ports, differential mode: 2 kV, common mode: 4.5 kV (criterion B)

Voltage dips immunity (DIP)

IEC 61000-4-11

Others

AC surge protection

Differential mode: 2 kV; common mode (4.5 kV); wave form 1.2/50 µs; criterion B

DC surge protection

  • Reserved BLVD expansion port: differential mode: 10 kA, common mode: 20 kA, 8/20 µs
  • DC load fuse output port: differential mode: 2 kV, common mode: 4.5 kV; wave form 1.2/50 µs; criterion B

Safety

Compliant with IEC/EN60950-1 and GB4943 and passed the VCCI certification

Mean time between failures (MTBF)

200,000 hours

Structure

Cabinet dimensions (H x W x D)

175x482x362 mm

Weight

≤ 20 kg (excluding rectifiers)

Protection level

IP20

Installation mode

Horizontally installed in a 19-inch cabinet

Cabling

Routed from the front and rear

Maintenance mode

Maintained from the front

Heat dissipation mode

Nature heat dissipation

Additional information

Brand

Huawei

Reviews

There are no reviews yet.

Be the first to review “ETP48200-C4A3”

Your email address will not be published. Required fields are marked *

  −  4  =  2

Back to Top

Search For Products