MA5801-GP16-H2 is a box-shaped(1U) OLT, which houses integrated control and service module, 1 pluggable fan module, 2 pluggable power modules,  16 GPON ports, 4 GE/10GE Uplink ports, 4 common interfaces

Description

MA5801-GP16-H2 Overview

With the continuous promotion of new services, such as 4K/VR videos, home networks, and network cloudification, optical fiber access has become an important means for countries around the world to popularize broadband networks. As optical fiber access nodes keep moving closer to end users, OLTs are closer to end users. Deployment scenarios are complex and diversified. In this case, network needs OLTs with small volume and low density.

The MA5801-GP16-H2 is a compact box-shaped OLT. It provides multiple fiber to the home (FTTH) solutions to meet the requirements of economical and efficient network construction. It can be flexibly deployed in fast fixed mobile convergence (FMC) scenario, national broadband coverage scenario, and enterprise’s all-optical campus scenario.

 

MA5801-GP16-H2 Ports

GP16

 

Port Name Silk Screen Number of Ports Function
DC power port 2 Connects to –48/–60 V DC power.
AC power port 2 Connects to 110/220 V AC power.
Reset button RESET 1 This button is used to reset the board manually. Resetting the board interrupts the services. Hence, exercise caution when using the reset button.
GPON port PON: 0–15 16 Provides 16 GPON ports for GPON service access.
Upstream port (10GE/GE optical) 10GE/GE: 0–3 4 Provides 4 10GE/GE ports for upstream transmission.
GE maintenance network port ETH 1 10/100/1000M BASE-T maintenance port. Connected to the Ethernet port of the maintenance terminal.
RS-232 serial port/RS-485 monitoring serial port CON/ESC 1 Connected to the serial port of the maintenance terminal/Connected to the serial port of the monitored device.
TOD port TOD 1 Connected to the lower stratum clock.
Environment monitoring port ALM 1 Connected to digital sensors.

 

MA5801-GP16-H2 Product Highlights

Lightweight and small size
The lightweight OLT weighs less than 5 kg and occupies 1 U installation space. It can be flexibly adapted to various scenarios.

High density, supporting 16 GPON ports
Supports 16 GPON service ports and works with GPON optical modules to implement GPON access.

Dual power supplies, high reliability
Supports dual AC or DC power supplies, providing flexible power supply and high reliability.

Easy installation and flexible deployment
The matching F01M50 mini outdoor cabinet can be installed on a pole, tower, or wall, facilitating installation and reducing engineering costs.

 

MA5801-GP16-H2 Primary Features

Layer 2 features
VLAN+MAC forwarding SVLAN+CVLAN forwarding
PPPoE+ DHCP option82
Layer 3 features
Static route RIP/RIPng
OSPF/OSPFv3 IS-IS
BGP/BGP4+ ARP
DHCP relay VRF
Multicast
IGMP v2/v3 IGMP Proxy/Snooping
MLD v1/v2 MLD Proxy/Snooping
VLAN-based IPTV multicast IPv4 PIM and PIM-SSM
QoS
Traffic classification Priority processing
trTCM-based traffic policing WRED
Traffic shaping HQoS
PQ/WRR/PQ+WRR ACL
IPv6
IPv4/IPv6 dual stack IPv6 L2 and L3 forwarding
DHCPv6 relay
System reliability
GPON Type B/Type C protection ERPS (G.8032)
2 power boards for redundancy protection In-service board fault detection and rectification
Application security
802.1x AAA
Clock and Time Feature (V100R021C00 and later versions)
Synchronous Ethernet 1588v2

NOTE:

This feature is supported only by products with a clock daughter board.

Aggregation
Aggregation management
Item MA5801-GP16-H2
Power supply mode
  • DC power supply (dual backup)
  • AC power supply (dual backup)
Working voltage range
  • DC power supply: –38.4 V to –72 V
  • AC power supply: 100–240 V
Rated voltage
  • DC power supply: –48 V/–60 V
  • AC power supply: 110 V/220 V
Maximum input current
  • DC power supply: 6 A
  • AC power supply: 2.5 A
Ambient temperature –40°C to +65°C The device can start up at a lowest temperature of –25°C.
NOTE:
The ambient temperature refers to the temperature measured at the air intake vent of a service subrack.
Ambient humidity 5%–95% RH
Atmospheric pressure 70–106 kPa
Altitude < 4000 m. The air density varies with the altitude and will affect the heat dissipation of a device. Therefore, the working environment temperature of the device varies with the altitude.
System switching capacity 140 Gbit/s
MAC addresses 32768
Access ONT 1024
IPv4 routing table 8192
IPv6 routing table 4096
ARP table 16384
Bit error rate (BER) in full load A BER smaller than 10 e-10 for a port that transmits data in full load
Upstream ports 4 GE/10GE
Service ports 16 GPON
System reliability specifications System availability for the typical configuration: > 99.999% Mean time between failures (MTBF): about 62 years
NOTE:
Due to different network environments and different boards used by devices, the preceding MTBF (62 years) of the MA5801 is only for reference. The preceding values are only for reference. For details, contact the related Huawei engineers.
Power consumption DC power supply:
  • Static power consumption: 52W
  • Typical power consumption: 91W
  • Maximum power consumption: 135W
AC power supply:
  • Static power consumption: 55W
  • Typical power consumption: 95W
  • Maximum power consumption: 140W
NOTE:
The power consumption of a product is tested in the following conditions:
  • Static power consumption: 25°C, no optical module in optical ports, and no service.
  • Typical power consumption: 25°C, 4 x 10GE(10kM) upstream ports, 16 x GPON(CLASS C+) ports on the user side, full services, and maximum traffic.
  • Maximum power consumption: 65°C, 4 x 10GE(10kM) upstream ports, 16 x GPON(CLASS C+) ports on the user side, full services, and maximum traffic.
Dimensions (H x W x D) Excluding mounting ears: 43.6 mm × 442 mm×220 mm Including IEC mounting ears: 43.6 mm × 482.6 mm × 220 mm Including ETSI mounting ears: 43.6 mm × 531 mm × 220 mm
Weight (full configuration)
  • DC power supply: 4.2 kg
  • AC power supply: 4.6 kg

What are the uplink board of the MA5800?

NXED:8-10GE uplink board
NCEB: 2-port Enhanced 100GE Uplink Interface Board

What QoS features are supported?

The QoS model implemented on the MA5800 is the differentiated service (DiffServ) model.
This model is based on priorities. In this model, the network identifies each data stream and provides corresponding QoS guarantees for the data streams. Traffic classification and priority marking are the prerequisites for using this model.
This model involves simple packet processing and is highly extendible. It is used for the following services:
*VoD
*Streaming media
*VoIP
*Video conferencing
*Private-line services

What service boards are supported for MA5800 series OLT?

GPON Board: GPHF/GPUF/GPLF/GPSF
XGPON Board: XGHD
GPON&XGPON combo Board: CGHF
XGS-PON Board: XSHF/XSHD
XGS-PON&GPON combo Board: CSHF
Flex-PON Board: FLHF

What's the power module for MA5800 series OLT?

MA5800-X2: PISB-AC power module PISA: DC power module
MA5800-X7/X15/X17: PILA, -48V DC power module

How to add local digitmap for Huwei ONT?

Because the specific ONT model is unknown, you can refer to the general ONT configuration method for configuring the ONT digitmap.
1. Log in to the WebUI of the Huawei ONT.
2. In the navigation tree on the left, choose Advanced Configuration > Voice > VoIP Basic Configuration. In the pane on the right, parameters of a VoIP interface can be configured, including the IP addresses of the primary server and secondary server, and digitmap.

Additional information

Weight 9 kg
Dimensions 59 × 39 × 26 cm
Brand

Huawei

Warranty

12 Months

Reviews

There are no reviews yet.

Be the first to review “MA5801-GP16-H2”

Your email address will not be published. Required fields are marked *

47  −  46  =  

Back to Top

Search For Products

Product has been added to your cart