Description
CE12804 overview
CE12804 is one of the Huawei CE12800 switches, which comes with 4 service slots.
CloudEngine 12800 (CE12800 for short) series switches are next-generation, high-performance core switches designed for data center networks and high-end campus networks. Using Huawei’s next-generation VRP8 operating system, CE12800 series switches provide stable, reliable, and secure high-performance Layer 2/Layer 3 switching capabilities to help build an elastic, virtualized, and high-quality network.
CE12800 series switches use an advanced hardware architecture design and provide 100GE/40GE/10GE/GE line cards with various port densities. The switches support high-density access of high-speed servers and aggregation of TOR switches, providing high performance and large capacity for data center networks.
CE12800 series switches use an industry-leading Clos architecture and a strict front-to-back airflow design to provide industrial-grade reliability. The switches also provide comprehensive virtualization capabilities and extensive data center service features. Moreover, they adopt multiple innovative energy-saving technologies to greatly reduce power consumption.
CE12808S fast spec
Switching capacity: 45/258 Tbit/s
Forwarding capacity: 17,280 Mpps
Operating voltage: AC: 90 V to 290 V DC: -40 V to -72 V HVDC: 188 V to 288 V
Max. power supply (W): 6000
CE12804 appearance
1. CE12800 series switches chassis header, showing the following:
|
2. Indicators | 3. CMU
|
4. MPU
|
5. LPUs
|
6. Front ESD jack
NOTE: When maintaining components at the front of a chassis, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack. |
7. Air intake area for SFUs in the CE12804 chassis (See Airflow for heat dissipation of the SFUs (side view) for the heat dissipation mechanism.) | 8. Power modules
The CE12804 chassis supports four power modules.
|
9. Cable management frame
NOTE: Cable management frames are installed on the left and right sides of a chassis to route cables in each slot. |
10. Fan modules
|
11. SFU
|
12. Power distribution unit | 13. Rear ESD jack
NOTE: When maintaining components at the rear of a chassis, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack. |
14. Two ground points for a dual-hole ground lug, with a yellow grounding label attached
NOTE: To protect a chassis from lightning and electromagnetic interference, use Ground Cable to ground the chassis. |
15. Handle
NOTE: When installing a chassis into a cabinet/rack, you can drag the chassis by the handle at the rear of the chassis. |
16. Two power switches NOTE: It is recommended to turn on both switches to power on the device. Both switches must be turned off to power off the device. |
17. Serial number label |
18. MAC address label |
– | – |