NE40E-X3A AC

PN 02350FML

NE40E-X3A Integrated AC Chassis Components (Including Dual AC Power)

Shenzhen Warehouse
lead time 3-5 days
- +
Overview

Item

NE40E-X3A AC

Dimensions (H x W x D)

  • (6 U) 264 mm x 442 mm x 710 mm (10.39 in. x 17.40 in. x 27.95 in.) (Chassis main body)
  • DC: (6 U) 264 mm x 442 mm x 758 mm (10.39 in. x 17.40 in. x 29.84 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
  • AC: (6 U) 264 mm x 442 mm x 770 mm (10.39 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)

Weight (empty)

26 kg (57.33 lb)

Weight (full configuration)

  • DC: 72.1 kg (158.98 lb)
  • AC: 74.7 kg (164.71 lb)

Cabinet installation standard

Can be installed in a standard 19" 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.

Typical power consumption

1120 W (fully configured with LPUF-200s)

Typical heat dissipation

3633.8 BTU/hour (fully configured with LPUF-200s)

DC input voltage

  • input voltage range: –40 V to –72 V
  • input rated voltage: –48 V/ –60 V

AC input voltage

  • input voltage range: 180 V to 264 V
  • input rated voltage: 200 V to 240 V

HVDC input voltage

  • input voltage range: 192 to 288VDC
  • input rated voltage: 240 VDC

MTBF

22.85 years

MTTR

0.5 hours

Availability

0.999997502

Slot quantity

5

Redundant MPUs

1:1

Redundant Switch fabrics

N/A

Redundant fans

Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)

Redundant power supply

1+1

Forwarding performance

900 Mpps (LPUF-200)

Switching capacity

2.76 Tbps

Operating temperature

  • Long-term: 0°C to 45°C (32°F to 113°F)
  • Short-term: –5°C to +55°C (23°F to131°F)
  • Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)

Storage temperature

–40°C to +70°C (–40°F to +158°F)

Relative operating humidity

  • Long term: 5% to 85% RH, non-condensing
  • Short term: 5% to 95% RH, non-condensing

Relative storage humidity

5% to 95% RH, non-condensing

Long-term operating altitude

<= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)

Storage altitude

Less than 5000 m (16404 ft.)