NE40E-X8A DC

NE40E-X8A DC

NE40E-X8A Integrated Chassis DC Components(Including 2 Fan Tray)

SKU: 9402 PN: 02350AFW Category:

Description

Item NE40E-X8A DC
Cabinet installation standard Can be installed in a standard 19″ 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
[2T bundle]Can be installed in a standard 19″ 1000 mm-deep cabinet,part number is 02115109(CR5B0N610E60)
Typical power consumption 4110 W (fully configured with LPUF-240s)
4770 W (fully configured with LPUF-480s)
6520 W (fully configured with LPUI-1Ts)
11100 W (fully configured with LPUI-2Ts)
Typical heat dissipation 13334.6 BTU/hour (fully configured with LPUF-240s)
15475.9 BTU/hour (fully configured with LPUF-480s)
21153.6 BTU/hour (fully configured with LPUI-1Ts)
36013.1 BTU/hour (fully configured with LPUI-2Ts)
DC input voltage input voltage range: –40 V to –72 V
input rated voltage: –48 V/ –60 V
AC input voltage input voltage range: 180 V to 264 V
input rated voltage: 200 V to 240 V
HVDC input voltage input voltage range: 192 to 288V,264 to 400V
input rated voltage: 240 V/380 V
MTBF 22.32 years
MTTR 0.5 hours
Availability 0.999997443
Slot quantity 12
Redundant MPUs 0.042361111
Redundant Switch fabrics 3+1
Redundant fans [1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
[2T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
Redundant power supply [1T bundle] DC: 5+1
[1T bundle] HVDC&AC: 4+1
[2T bundle] DC: 7+1
[2T bundle] HVDC&AC: 5+1
Forwarding performance 2800 Mpps (LPUF-240)
Switching capacity 25.16 Tbps (LPUI-1T)
51.2 Tbps (LPUI-2T)
Operating temperature Long-term: 0°C to 45°C (32°F to 113°F)
Short-term: –5°C to +55°C (23°F to131°F)
Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h)
Storage temperature –40°C to +70°C (–40°F to +158°F)
Relative operating humidity Long term: 5% to 85% RH, non-condensing
Short term: 5% to 95% RH, non-condensing
Relative storage humidity 5% to 95% RH, non-condensing
Long-term operating altitude <= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].)
Storage altitude Less than 5000 m (16404 ft.)
Dimensions (H x W x D) (21 U) 930 mm x 442 mm x 650 mm (36.61 in. x 17.40 in. x 25.59 in.) (Chassis main body)
(21 U) 930 mm x 442 mm x 750 mm (36.61 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
[2T bundle](21 U) 930 mm x 442 mm x 941 mm (36.61 in. x 17.40 in. x 37.05 in.) (Dimensions of the chassis body together with cable trays and front and back attachments and noise reduction module)
Weight (empty) DC: 68.1 kg (150.16 lb) (without filler panels)
HVDC&AC: 63.7 kg (140.46 lb) (without filler panels)
Weight (full configuration) [1T bundle] DC:209 kg (460.85 lb)
[1T bundle]HVDC&AC:206.5 kg (455.33 lb)
[2T bundle]DC:242kg (533.51 lb)
[2T bundle]AC&HVDC:234.4kg(516.76 lb)

Additional information

Weight 70.0000 kg
Dimensions 93.0000 × 45.0000 × 75.0000 cm

2 reviews for NE40E-X8A DC

  1. 5 out of 5

    Fajardo

    Original new NE40E-X8A, with good package condition.

  2. 5 out of 5

    David

    Delivered with the test report, good.