Description
OSN 9800 U16 overview
Intended for 100G and beyond 100G optical networks, the OSN 9800 U16 subrack is a next-generation large-capacity OTN product that integrates ASON, OTN, and packet functions. It is applicable to various networks, including super-backbone, backbone, and metro networks.
OSN 9800 U16 subrack areas and slots
Boards need to be installed in the designated slots in a subrack. The subrack runs on -48 V DC or -60 V DC and is divided into multiple areas in which designated PIU boards in different slots power boards. The subrack can be installed in an ETSI cabinet or a 19-inch cabinet.
U16 can be used as a service subrack or a central cluster chassis. The function of a U16 subrack depends on the installed system control board. If the TNS1CTU board is installed, the U16 subrack is a common service subrack.
Descriptions of the areas and slots in the OptiX OSN 9800 U16 subrack (service subrack)
Area | Composition | Slot | Function |
System control and cross-connect board area | 4 PIU boards | IU68, IU69, IU80, IU81 | They supply power to the subrack. |
The PIU boards in slots IU68 and IU80, and the PIU boards in slots IU69 and IU81 are in mutual backup. Therefore, the failure of any power input to the subrack does not affect the normal operation of the subrack. | |||
1 EFI board | IU79 | The EFI board provides maintenance and management interfaces. | |
2 CTU boards (TNS1CTU) | IU70, IU78 | The CTU boards manage the subrack, provide a clock for service boards, and implement inter-NE communication. | |
Two CTU boards are configured for mutual backup. | |||
7 cross-connect boards (TNS1XCS/TNS1UXCS) | IU71-IU77 | The cross-connect boards’ groom services between service boards. | |
Cross-connect boards are configured in M: N backup mode. | |||
When a U16 subrack is used as a pure regeneration subrack, no cross-connect board is required. | |||
Fan area | 2 fan tray assemblies | IU90, IU91 | Fan tray assemblies are used to ventilate the equipment. |
Fiber-routing areas | 2 fiber troughs | N/A | Fiber patch cords connecting to boards are routed to the left or right side of the equipment through the upper- and lower-side fiber troughs. |
Service board area | 14 service boards | IU1-IU14 | Service boards need to be configured based on the service plan and all of them are installed in the service board area. |
Descriptions of the areas and slots in the OptiX OSN 9800 U16 subrack (central cluster chassis)
Area | Composition | Slot | Function |
System clock and control board area | 4 PIU boards | IU68, IU69, IU80, IU81 | They supply power to the subrack. |
The PIU boards in slots IU68 and IU80, and the PIU boards in slots IU69 and IU81 are in mutual backup. Therefore, the failure of any power input to the subrack does not affect the normal operation of the subrack. | |||
1 EFI board | IU79 | The EFI board provides maintenance and management interfaces. | |
2 CTU boards (TNS2CTU) | IU70, IU78 | The CTU boards manage the subrack, provide a clock for service boards, and implement inter-NE communication. | |
Two CTU boards are configured for mutual backup. | |||
2 system clock distribution boards (TNS1Std) | IU75, IU77 | Implements system clock processing and distribution for a cluster. | |
Fan tray assemblies are used to ventilate the equipment. | |||
Fiber patch cords connecting to boards are routed to the left or right side of the equipment through the upper- and lower-side fiber troughs. | |||
Cluster cross-connect board area | 14 cross-connect boards (TNU1CCXCS) | IU1-IU14 | Implements centralized grooming of inter-subrack services for a cluster. |
OSN 9800 U16 cross-connect capacities
This topic describes the maximum cross-connect capacity of a service slot and an OptiX OSN 9800 U16 subrack.
When an OptiX OSN 9800 U16 subrack functions as a service subrack: An OptiX OSN 9800 U16 subrack supports grooming of ODUk (k = 0, 1, 2, 2e, 3, 4, flex) services, packet services, and VC-3/VC-4/VC-12 services. Slots IU1-IU14 provide the same cross-connect capacity.
Maximum Cross-Connect Capacity of Each Slot | Maximum Cross-Connect Capacity of Each Subrack | ||||||
ODUk | VC-4 | VC-3/VC-12a | Packet | ODUk | VC-4 | VC-3/VC-12 | Packet |
400 Gbit/s | 80 Gbit/s | 80 Gbit/s | 200 Gbit/s | 5.6 Tbit/s | 1.12 Tbit/s | 80 Gbit/s | 2.8 Tbit/s |
a: All service slots share a bandwidth of 80 Gbit/s. |
Service types, service rates, and corresponding service boards supported by the OptiX OSN 9800 U16 Subrack
Service Category | Service Type | Service Rate | Board | Standard Compliance |
SDH | STM-1 | 155.52 Mbit/s | T130, TNV6T216, T210, T220, T230, EC116, S216, TNV3G220, G216, G230 | ITU-T G.707 |
ITU-T G.691 | ||||
STM-4 | 622.08 Mbit/s | T130, T216, T210, T220, T230, EC404, S216, TNV3G220, G216, G230 | ITU-T G.957 | |
STM-16 | 2.5 Gbit/s | T130, TNV6T216, T210, T220, T230, S216, TNV3G220, G216, G230 | ITU-T G.693 | |
STM-64 | 9.95 Gbit/s | T216, TNV6T216, T210, T220, T230, G210, G220, S208, S216, G216, G230 | ITU-T G.783 | |
STM-256 | 39.81 Gbit/s | T302 | ITU-T G.825 | |
SONET | OC-3 | 155.52 Mbit/s | T130, T210, T220, T230, T216, TNV3G220, G216, G230 | GR-253-CORE GR-1377-CORE ANSI T1.105 |
OC-12 | 622.08 Mbit/s | T130, T210, T220, T230, TNV6T216, TNV3G220, G216, G230 | ||
OC-48 | 2.5 Gbit/s | T130, T210, T220, T230, TNV6T216, TNV3G220, G216, G230 | ||
OC-192 | 9.95 Gbit/s | T216, T210, T220, T230, G210, G220, G216, G230 | ||
OC-768 | 39.81 Gbit/s | T302 | ||
Ethernet service | FE (optical signal) | Interface rate: 125 Mbit/s Service rate: 100 Mbit/s | T130, T210, TNV6T216, T220, T230, T220E, E124, E224, EMS20, TNV3G220, G216, G230 | IEEE 802.3u |
FE (electrical signal) | Interface rate: 125 Mbit/s Service rate: 100 Mbit/s | E124, G216 | ||
GE (optical signal) | Interface rate: 1.25 Gbit/s Service rate: 1 Gbit/s | T130, T210, TNV6T216, T220, T230, T220E, E124, E224, EMS20, TNV3G220, G216, G230 | IEEE 802.3z | |
GE (electrical signal) | Interface rate: 1.25 Gbit/s Service rate: 1 Gbit/s | T130, T210, TNV6T216, T220, T230, T220E, E124, E224, EMS20, TNV3G220, G216, G230 | ||
10GE WAN | 9.95 Gbit/s | T216, T210, T220, T230, G210, G220, G216, G230 | IEEE 802.3ae | |
10GE LAN | 10.31 Gbit/s | T216, T210, T220, T230, T220E, E208, E212, EMS20, G210, G220, E224, G216, G230 | ||
25GE | 25.78 Gbit/s | TNV6T216, TNV7T220, TNV6T230, TNV3E224, G216, G230 | IEEE 802.3by | |
40GE | 41.25 Gbit/s | T302, E302, TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T502 | IEEE 802.3ba | |
50GE | 51.5625 Gbit/s | T502, TNV3E402 | ||
100GE | 103.125 Gbit/s | T401, T402, T404, E401, G402, G404, E402, T502 | ||
200GE | 206.25 Gbit/s | T502 | ||
400GE | 412.5 Gbit/s | T601 | ||
Flexible Ethernet service (FlexE) | FlexE Unaware (50G) | 51.5625 Gbit/s | T502 | IA Flex Ethernet 2.1 |
FlexE Unaware (100G) | 103.125 Gbit/s | TNV8T402, TNV8T404, T502 | ||
FlexE Aware (200G) | 206.25 Gbit/s | T502 | ||
SAN service | FDDI | 125 Mbit/s | T130, T210, TNV6T216, T220, T230, TNV3G220, G216, G230 | ISO 9314 |
ESCON | 200 Mbit/s | T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 | ANSI X3.296 | |
FICON | 1.06 Gbit/s | T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 | ANSI X3.230 | |
FICON Express | 2.12 Gbit/s | T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 | ANSI X3.303 | |
FC100 | 1.06 Gbit/s | T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 | ||
FC200 | 2.12 Gbit/s | T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 | ||
FC400/FICON4G | 4.25 Gbit/s | T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 | ||
FC800/FICON8G | 8.5 Gbit/s | T216, T210,TNV6T216, T220, T230, G210, G220, G216, G230 | ||
FC1200 | 10.51 Gbit/s | T216, T210,TNV6T216, T220, T230, G210, G220, G216, G230 | ||
FC1600 | 14.025 Gbit/s | T210, T220, T230,TNV6T216, TNV3G220, G216, G230 | ||
FC3200 | 28.05 Gbit/s | TNV6T216, TNV7T220, TNV6T230, G216, G230 | ||
OTN service | OTU1 | 2.67 Gbit/s | T130, T210, T220, T230,TNV6T216, TNV3G220, TNV3S216, TNV4S216, TNV6S216, G216, G230 | ITU-T G.709 |
OTU2 | 10.71 Gbit/s | T216, T210, T220, T230, G210, G220, G216, G230 | ITU-T G.959.1 | |
OTU2e | 11.10 Gbit/s | T216, T210, T220, T230, G210, G220, G216, G230 | GR-2918-CORE | |
OTU3 | 43.02 Gbit/s | T302 | ||
OTU4 | 111.81 Gbit/s | T401, T402, T404, G402, G404, T502 | ||
Video service | DVB-ASI | 270 Mbit/s | T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 | EN 50083-9 |
SDI | 270 Mbit/s | T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 | SMPTE 259M | |
HD-SDI | 1.49 Gbit/s | T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 | SMPTE 292M | |
HD-SDIRBR | 1.49/1.001 Gbit/s | T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 | ||
3G-SDI | 2.97 Gbit/s | T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 | SMPTE 424M |
Additional information
Weight | 40 kg |
---|---|
Dimensions | 85 × 45 × 30 cm |
Specifications | OSN 9800 U64 Standard | OSN 9800 U32 Standard | OSN 9800 U16 | ||
Subrack dimensions (mm) | 2200 (H) x 600 (W) x 600 (D) (the subrack is integrated into a cabinet) | 1900 (H) x 498 (W) x 295 (D) (without cabinet) | 847 (H) x 442 (W) x 295 (D) (without cabinet) | ||
Suitable cabineta | The subrack is integrated into a cabinet, and no additional cabinet needs to be configured. | ETSI 300/600 cabinets, such as N63B and N66B | ETSI 300/600 cabinets, such as N63B and N66B | ||
19-inch cabinet | |||||
Max. number of slots for service boards | 64 | 32 | 14 | ||
Switching capability | Optical | N/A | |||
Electrical | 25.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4, flex) | 12.8 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4, flex) | 5.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4, flex) | ||
25.6 Tbit/s OSUflex | 12.8 Tbit/s OSUflex | 2.8 Tbit/s packet services | |||
25.6 Tbit/s packet services | 12.8 Tbit/s packet services | 1.12 Tbit/s VC-4 | |||
10.24 Tbit/s VC-4 | 5.12 Tbit/s VC-4 | 80 Gbit/s VC-3/VC-12 | |||
160 Gbit/s VC-3/VC-12 | 160 Gbit/s VC-3/VC-12 | ||||
Max. number of wavelengths | Fixed grid: 120 wavelengths @50 GHz grid | ||||
Flexible grid: The maximum number of wavelengths is related to the width of the flex channel. | |||||
Center wavelength range | DWDM system: 1524.50 nm to 1572.06 nm (super C-band) | ||||
CWDM system: 1471 nm to 1611 nm (S+C+L Band) | |||||
Max. rate per channel | 400 Gbit/s (OTUC4) | ||||
Service type | Synchronous digital hierarchy (SDH)/synchronous optical network (SONET), Ethernet, storage area network (SAN), optical transport network (OTN), and video | ||||
Packet service capacity | Support E-Line/E-LAN (MEF) and VPWS/VPLS (IETF) | ||||
Support MPLS-TP | |||||
Number of MPLS tunnel: 64×1024 | |||||
Number of PW: 64×1024 | |||||
Number of E-Line: 32×1024 | |||||
Number of E-LAN: 8×1024 | |||||
Line rate | 2.5Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/s, 200 Gbit/s and 400 Gbit/s | ||||
Supported pluggable optical modules | eSFP, SFP+, XFP, CFP, CXP, CFP2, QSFP2, SFP28, QSFP+, QSFP-DD | ||||
Topology | Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh | ||||
Redundancy and protection | Equipment level protection | Power redundancy, fan redundancy, cross-connect board redundancy, communication control and clock processing unit redundancy | |||
Network level protection (OTN) | Client 1+1 protection, ODUk SNCP, OSUflex SNCP, tributary SNCP, intra-board 1+1 protection, LPT | ||||
Network level protection (Packet) | ERPS, LAG, MC-LAG, LMSP, MC-LMSP, MRPS, PW APS/FPS, MC-PW APS, Tunnel APS, LPT | ||||
Network level protection (SDH) | LMSP, SNCP, Ring MSP | ||||
Network level protection (EoS) | LAG, DLAG, LCAS, LPT, STP/RSTP, BPS, PPS | N/A | |||
Optical power management | ALS, IPA, IPA of Raman System | ||||
Synchronization | Synchronous Ethernet clock | ||||
IEEE 1588v2 | |||||
ITU-T G.8275.1 | |||||
ASON | Electrical-Layer ASON | ||||
Optical-Layer ASON | |||||
TSDN | Online Service Provisioning | ||||
Survivability Analysis | |||||
BOD | |||||
IP and Optical Collaboration | |||||
Submarine features | Supports the application of extended C band in submarine scenarios. | ||||
Nominal working voltage | Nominal working voltage: -48V DC/-60V DC | ||||
Working voltage range: | |||||
-48 V DC: -40 V to -57.6 V | |||||
-60 V DC: -48 V to -72 V | |||||
Operation environment | Subrack temperature: | Subrack temperature: | |||
Long-term operation: 5°C (41 °F) to 40°C (104 °F) | Long-term operation: 5°C (41 °F) to 40°C (104 °F) | ||||
Short-term operationb: -5°C (23 °F) to 45°C (113 °F) | Short-term operationb: -5°C (23 °F) to 50°C (122 °F) | ||||
Relative humidity: | Relative humidity: | ||||
Long-term operation: 5% to 85% | Long-term operation: 5% to 85% | ||||
Short-term operationb: 5% to 90% | Short-term operationb: 5% to 90% | ||||
Mean Time To Repair (MTtr) | 4 hours | ||||
Mean Time Between Failure (MTBF) | 66.83 years | ||||
Availability | 0.999993167 | ||||
a: The ETSI/19-inch standard defines only part of the cabinet dimensions. Therefore, the distance between the cabinet column and door plate varies depending on cabinet manufacturers. For details about the dimensions of different subracks, see the detailed description of each subrack. | |||||
b: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days. |
Service capabilities supported by the OSN 9800 U Series Subrack
Service Category | Service Type | Max. Number of Service Inputs Supported by the OSN 9800 U64 Standard | Max. Number of Service Inputs Supported by the OSN OSN 9800 U32 Standard | Max. Number of Service Inputs Supported by the OSN 9800 U16 Subrack |
SDH | STM-1 | 1920 | 960 | 420 |
STM-4 | 1920 | 960 | 420 | |
STM-16 | 1920 | 960 | 420 | |
STM-64 | 1920 | 960 | 420 | |
STM-256 | 128 | 64 | 28 | |
SONET | OC-3 | 1920 | 960 | 420 |
OC-12 | 1920 | 960 | 420 | |
OC-48 | 1920 | 960 | 420 | |
OC-192 | 1920 | 960 | 420 | |
OC-768 | 64 | 32 | 14 | |
Ethernet service | FE (optical signal) | 1920 | 960 | 420 |
GE (optical signal) | 1920 | 960 | 420 | |
GE (electrical signal) | 1920a | 960a | 420a | |
10GE WAN | 1920 | 960 | 420 | |
10GE LAN | 1920 | 960 | 420 | |
25GE | 1024 | 512 | 256 | |
40GE | 256 | 128 | 56 | |
50GE | 128 | 64 | 28 | |
100GE | 256 | 128 | 56 | |
200GE | 128 | 64 | 28 | |
400GE | 64 | 32 | 14 | |
Flexible Ethernet service (FlexE) | FlexE Unaware (50G) | 128 | 64 | 28 |
FlexE Unaware (100G) | 256 | 128 | 56 | |
FlexE Aware (200G) | 128 | 64 | 28 | |
SAN service | FDDI | 1920 | 960 | 420 |
ESCON | 1920 | 960 | 420 | |
FICON | 1920 | 960 | 420 | |
FICON Express | 1920 | 960 | 420 | |
FC100 | 1920 | 960 | 420 | |
FC200 | 1920 | 960 | 420 | |
FC400/FICON4G | 1920 | 960 | 420 | |
FC800/FICON8G | 1920 | 960 | 420 | |
FC1200 | 1920 | 960 | 420 | |
FC1600 | 768 | 384 | 168 | |
FC3200 | 384 | 192 | 84 | |
OTN service | OTU1 | 1920 | 960 | 420 |
OTU2 | 1920 | 960 | 420 | |
OTU2e | 1920 | 960 | 420 | |
OTU3 | 128 | 64 | 28 | |
OTU4 | 256 | 128 | 56 | |
Video service | DVB-ASI | 1920 | 960 | 420 |
SDI | 1920 | 960 | 420 | |
HD-SDI | 1920 | 960 | 420 | |
HD-SDIRBR | 1920 | 960 | 420 | |
3G-SDI | 1920 | 960 | 420 | |
3G-SDIRBR | 1920 | 960 | 420 | |
a:This value only refers to the maximum tributary service capacity when the subrack is fully configured with tributary boards but with no line boards. |