OSN 9800 U32 Standard

OSN 9800 U32 Standard

Huawei OptiX OSN 9800 U32 Standard Subrack

Huawei

SKU: 2012873 Category:

Description

OSN 9800 U32 Standard overview

Intended for 100G and beyond 100G optical networks, the 9800 U32 Standard subrack is a next-generation large-capacity OTN product that integrates ASON, OTN, and packet functions. It is applicable to various networks, including super-backbone, backbone, and metro networks.

 

OSN 9800 U32 Standard subrack areas and slots

Boards need to be installed in the designated slots in the subrack. 9800 U32 subracks are classified into two types, namely 9800 U32 Standard and 9800 U32 Enhanced.

OSN 9800 U32 Standard subrack areas and slots

Descriptions of the areas and slots in the OptiX OSN 9800 U32 Standard subrack

Area Composition Slot Function
Power and interface area 1 EFI (TNV1EFI/TNV2EFI) board and 10 PIU boards PIU: IU100-IU104, IU106-IU110 The PIU boards are in mutual backup. Therefore, the failure of any power input to the equipment does not affect the normal operation of the equipment. NOTE: The PIU boards on the left and right sides of the EFI board are in mutual backup, for example, the PIU boards in slots IU100 and IU106, the PIU boards in slots IU101 and IU107, and so on. The EFI board provides maintenance and management interfaces.
EFI: IU105
Fan areas 4 fan(TNV1FAN) tray assemblies Lower portion: IU90, IU91 The fan tray assemblies are used to ventilate the equipment.
Upper portion: IU92, IU93
Fiber-routing areas 2 fiber troughs N/A Fiber patch cords connecting to boards are routed to the left or right side of the subrack through the upper- and lower-side fiber troughs.
Service board areas 32 service boards Lower portion: IU1-IU16 Service boards need to be configured based on the service plan and all of them are installed in the two service board areas. NOTE: Service boards installed in slots IU1-IU16 have their ejector levers on the right sides of the board front panels. Service boards installed in remaining slots in the two areas have their ejector levers on the left sides of the board front panels.
Upper portion: IU17-IU32
System control and cross-connect board area 2 CTU system control boards and 7 cross-connect boards Cross-connect boards: IU71-IU77 Cross-connect boards are configured in M:N backup mode. The cross-connect boards provide cross-connections for service boards. The system control boards are configured in 1+1 backup mode. The active system control board manages and provides a clock to all other boards in the equipment. It also provides for inter-NE communication. When a U32 Standard subrack is used as a pure regeneration subrack, no cross-connect board is required.
CTU: IU70, IU78

 

OSN 9800 U32 Standard cross-connect capacities

This topic describes the cross-connect capacity of a service slot and an OptiX OSN 9800 U32 subrack.

Subrack Type Maximum Cross-Connect Capacity of Each Slot Maximum Cross-Connect Capacity of Each Subrack
ODUk OSUflex VC-4 VC-3/VC-12a Packet ODUk OSUflex VC-4 VC-3/VC-12 Packet
U32 Standard 400 Gbit/s 400 Gbit/s 160 Gbit/s 160 Gbit/s 400 Gbit/s 12.8 Tbit/s 12.8 Tbit/s 5.12 Tbit/s 160 Gbit/s 12.8 Tbit/s
U32 Enhanced (2:5 mode) 1 Tbit/s 1 Tbit/s 160 Gbit/s 160 Gbit/s 400 Gbit/s 32 Tbit/s 32 Tbit/s 5.12 Tbit/s 160 Gbit/s 12.8 Tbit/s
U32 Enhanced (2:2 mode) 400 Gbit/s 400 Gbit/s 160 Gbit/s 160 Gbit/s 400 Gbit/s 12.8 Tbit/s 12.8 Tbit/s 5.12 Tbit/s 160 Gbit/s 12.8 Tbit/s
a: All service slots share a bandwidth of 160 Gbit/s.

Service types, service rates, and corresponding service boards supported by the OptiX OSN 9800 U32 Standard Subrack

Service Category Service Type Service Rate Board Standard Compliance
SDH STM-1 155.52 Mbit/s T130, TNV6T216, T210, T220, T230, EC116, S216, TNV3G220, G216, G230 ITU-T G.707
ITU-T G.691
STM-4 622.08 Mbit/s T130, T216, T210, T220, T230, EC404, S216, TNV3G220, G216, G230 ITU-T G.957
STM-16 2.5 Gbit/s T130, TNV6T216, T210, T220, T230, S216, TNV3G220, G216, G230 ITU-T G.693
STM-64 9.95 Gbit/s T216, TNV6T216, T210, T220, T230, G210, G220, S208, S216, G216, G230 ITU-T G.783
STM-256 39.81 Gbit/s T302 ITU-T G.825
SONET OC-3 155.52 Mbit/s T130, T210, T220, T230, T216, TNV3G220, G216, G230 GR-253-CORE GR-1377-CORE ANSI T1.105
OC-12 622.08 Mbit/s T130, T210, T220, T230, TNV6T216, TNV3G220, G216, G230
OC-48 2.5 Gbit/s T130, T210, T220, T230, TNV6T216, TNV3G220, G216, G230
OC-192 9.95 Gbit/s T216, T210, T220, T230, G210, G220, G216, G230
OC-768 39.81 Gbit/s T302
Ethernet service FE (optical signal) Interface rate: 125 Mbit/s Service rate: 100 Mbit/s T130, T210, TNV6T216, T220, T230, T220E, E124, E224, EMS20, TNV3G220, G216, G230 IEEE 802.3u
FE (electrical signal) Interface rate: 125 Mbit/s Service rate: 100 Mbit/s E124, G216
GE (optical signal) Interface rate: 1.25 Gbit/s Service rate: 1 Gbit/s T130, T210, TNV6T216, T220, T230, T220E, E124, E224, EMS20, TNV3G220, G216, G230 IEEE 802.3z
GE (electrical signal) Interface rate: 1.25 Gbit/s Service rate: 1 Gbit/s T130, T210, TNV6T216, T220, T230, T220E, E124, E224, EMS20, TNV3G220, G216, G230
10GE WAN 9.95 Gbit/s T216, T210, T220, T230, G210, G220, G216, G230 IEEE 802.3ae
10GE LAN 10.31 Gbit/s T216, T210, T220, T230, T220E, E208, E212, EMS20, G210, G220, E224, G216, G230
25GE 25.78 Gbit/s TNV6T216, TNV7T220, TNV6T230, TNV3E224, G216, G230 IEEE 802.3by
40GE 41.25 Gbit/s T302, E302, TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T502 IEEE 802.3ba
50GE 51.5625 Gbit/s T502, TNV3E402
100GE 103.125 Gbit/s T401, T402, T404, E401, G402, G404, E402, T502
200GE 206.25 Gbit/s T502
400GE 412.5 Gbit/s T601
Flexible Ethernet service (FlexE) FlexE Unaware (50G) 51.5625 Gbit/s T502 IA Flex Ethernet 2.1
FlexE Unaware (100G) 103.125 Gbit/s TNV8T402, TNV8T404, T502
FlexE Aware (200G) 206.25 Gbit/s T502
SAN service FDDI 125 Mbit/s T130, T210, TNV6T216, T220, T230, TNV3G220, G216, G230 ISO 9314
ESCON 200 Mbit/s T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 ANSI X3.296
FICON 1.06 Gbit/s T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 ANSI X3.230
FICON Express 2.12 Gbit/s T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230 ANSI X3.303
FC100 1.06 Gbit/s T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230
FC200 2.12 Gbit/s T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230
FC400/FICON4G 4.25 Gbit/s T130, T210,TNV6T216, T220, T230, TNV3G220, G216, G230
FC800/FICON8G 8.5 Gbit/s T216, T210,TNV6T216, T220, T230, G210, G220, G216, G230
FC1200 10.51 Gbit/s T216, T210,TNV6T216, T220, T230, G210, G220, G216, G230
FC1600 14.025 Gbit/s T210, T220, T230,TNV6T216, TNV3G220, G216, G230
FC3200 28.05 Gbit/s TNV6T216, TNV7T220, TNV6T230, G216, G230
OTN service OTU1 2.67 Gbit/s T130, T210, T220, T230,TNV6T216, TNV3G220, TNV3S216, TNV4S216, TNV6S216, G216, G230 ITU-T G.709
OTU2 10.71 Gbit/s T216, T210, T220, T230, G210, G220, G216, G230 ITU-T G.959.1
OTU2e 11.10 Gbit/s T216, T210, T220, T230, G210, G220, G216, G230 GR-2918-CORE
OTU3 43.02 Gbit/s T302
OTU4 111.81 Gbit/s T401, T402, T404, G402, G404, T502
Video service DVB-ASI 270 Mbit/s T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 EN 50083-9
SDI 270 Mbit/s T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 SMPTE 259M
HD-SDI 1.49 Gbit/s T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 SMPTE 292M
HD-SDIRBR 1.49/1.001 Gbit/s T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230
3G-SDI 2.97 Gbit/s T120S, T130, T210, T220, T230,TNV6T216, TNV3G220, G216, G230 SMPTE 424M

 

Additional information

Weight 68 kg
Dimensions 190 × 50 × 30 cm
Specifications OSN 9800 U64 Standard OSN 9800 U32 Standard OSN 9800 U16
Subrack dimensions (mm) 2200 (H) x 600 (W) x 600 (D) (the subrack is integrated into a cabinet) 1900 (H) x 498 (W) x 295 (D) (without cabinet) 847 (H) x 442 (W) x 295 (D) (without cabinet)
Suitable cabineta The subrack is integrated into a cabinet, and no additional cabinet needs to be configured. ETSI 300/600 cabinets, such as N63B and N66B ETSI 300/600 cabinets, such as N63B and N66B
19-inch cabinet
Max. number of slots for service boards 64 32 14
Switching capability Optical N/A
Electrical 25.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4, flex) 12.8 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4, flex) 5.6 Tbit/s ODUk (k = 0, 1, 2, 2e, 3, 4, flex)
25.6 Tbit/s OSUflex 12.8 Tbit/s OSUflex 2.8 Tbit/s packet services
25.6 Tbit/s packet services 12.8 Tbit/s packet services 1.12 Tbit/s VC-4
10.24 Tbit/s VC-4 5.12 Tbit/s VC-4 80 Gbit/s VC-3/VC-12
160 Gbit/s VC-3/VC-12 160 Gbit/s VC-3/VC-12
Max. number of wavelengths Fixed grid: 120 wavelengths @50 GHz grid
Flexible grid: The maximum number of wavelengths is related to the width of the flex channel.
Center wavelength range DWDM system: 1524.50 nm to 1572.06 nm (super C-band)
CWDM system: 1471 nm to 1611 nm (S+C+L Band)
Max. rate per channel 400 Gbit/s (OTUC4)
Service type Synchronous digital hierarchy (SDH)/synchronous optical network (SONET), Ethernet, storage area network (SAN), optical transport network (OTN), and video
Packet service capacity Support E-Line/E-LAN (MEF) and VPWS/VPLS (IETF)
Support MPLS-TP
Number of MPLS tunnel: 64×1024
Number of PW: 64×1024
Number of E-Line: 32×1024
Number of E-LAN: 8×1024
Line rate 2.5Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/s, 200 Gbit/s and 400 Gbit/s
Supported pluggable optical modules eSFP, SFP+, XFP, CFP, CXP, CFP2, QSFP2, SFP28, QSFP+, QSFP-DD
Topology Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh
Redundancy and protection Equipment level protection Power redundancy, fan redundancy, cross-connect board redundancy, communication control and clock processing unit redundancy
Network level protection (OTN) Client 1+1 protection, ODUk SNCP, OSUflex SNCP, tributary SNCP, intra-board 1+1 protection, LPT
Network level protection (Packet) ERPS, LAG, MC-LAG, LMSP, MC-LMSP, MRPS, PW APS/FPS, MC-PW APS, Tunnel APS, LPT
Network level protection (SDH) LMSP, SNCP, Ring MSP
Network level protection (EoS) LAG, DLAG, LCAS, LPT, STP/RSTP, BPS, PPS N/A
Optical power management ALS, IPA, IPA of Raman System
Synchronization Synchronous Ethernet clock
IEEE 1588v2
ITU-T G.8275.1
ASON Electrical-Layer ASON
Optical-Layer ASON
TSDN Online Service Provisioning
Survivability Analysis
BOD
IP and Optical Collaboration
Submarine features Supports the application of extended C band in submarine scenarios.
Nominal working voltage Nominal working voltage: -48V DC/-60V DC
Working voltage range:
-48 V DC: -40 V to -57.6 V
-60 V DC: -48 V to -72 V
Operation environment Subrack temperature: Subrack temperature:
Long-term operation: 5°C (41 °F) to 40°C (104 °F) Long-term operation: 5°C (41 °F) to 40°C (104 °F)
Short-term operationb: -5°C (23 °F) to 45°C (113 °F) Short-term operationb: -5°C (23 °F) to 50°C (122 °F)
Relative humidity: Relative humidity:
Long-term operation: 5% to 85% Long-term operation: 5% to 85%
Short-term operationb: 5% to 90% Short-term operationb: 5% to 90%
Mean Time To Repair (MTtr) 4 hours
Mean Time Between Failure (MTBF) 66.83 years
Availability 0.999993167
a: The ETSI/19-inch standard defines only part of the cabinet dimensions. Therefore, the distance between the cabinet column and door plate varies depending on cabinet manufacturers. For details about the dimensions of different subracks, see the detailed description of each subrack.
b: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days.

 

 

Service capabilities supported by the OSN 9800 U Series Subrack

Service Category Service Type Max. Number of Service Inputs Supported by the OSN 9800 U64 Standard Max. Number of Service Inputs Supported by the OSN OSN 9800 U32 Standard Max. Number of Service Inputs Supported by the OSN 9800 U16 Subrack
SDH STM-1 1920 960 420
STM-4 1920 960 420
STM-16 1920 960 420
STM-64 1920 960 420
STM-256 128 64 28
SONET OC-3 1920 960 420
OC-12 1920 960 420
OC-48 1920 960 420
OC-192 1920 960 420
OC-768 64 32 14
Ethernet service FE (optical signal) 1920 960 420
GE (optical signal) 1920 960 420
GE (electrical signal) 1920a 960a 420a
10GE WAN 1920 960 420
10GE LAN 1920 960 420
25GE 1024 512 256
40GE 256 128 56
50GE 128 64 28
100GE 256 128 56
200GE 128 64 28
400GE 64 32 14
Flexible Ethernet service (FlexE) FlexE Unaware (50G) 128 64 28
FlexE Unaware (100G) 256 128 56
FlexE Aware (200G) 128 64 28
SAN service FDDI 1920 960 420
ESCON 1920 960 420
FICON 1920 960 420
FICON Express 1920 960 420
FC100 1920 960 420
FC200 1920 960 420
FC400/FICON4G 1920 960 420
FC800/FICON8G 1920 960 420
FC1200 1920 960 420
FC1600 768 384 168
FC3200 384 192 84
OTN service OTU1 1920 960 420
OTU2 1920 960 420
OTU2e 1920 960 420
OTU3 128 64 28
OTU4 256 128 56
Video service DVB-ASI 1920 960 420
SDI 1920 960 420
HD-SDI 1920 960 420
HD-SDIRBR 1920 960 420
3G-SDI 1920 960 420
3G-SDIRBR 1920 960 420
a:This value only refers to the maximum tributary service capacity when the subrack is fully configured with tributary boards but with no line boards.

1 review for OSN 9800 U32 Standard

  1. 4 out of 5

    Martin

    Such a intact packaging and affordable price, nice.


Add a review

has been added to your cart:
Checkout