Description
CE5855E-48T4S2Q overview
CE5855E-48T4S2Q Huawei CE5800 switch 48*GE RJ45, 4*10GE SFP+, 2*40GE QSFP+
$0.00 Original price was: $0.00.Current price is: $0.00.
CE5855E-48T4S2Q Huawei CE5800 switch 48*GE RJ45, 4*10GE SFP+, 2*40GE QSFP+
CE5855E-48T4S2Q Huawei CE5800 switch 48*GE RJ45, 4*10GE SFP+, 2*40GE QSFP+
Item | CE5855E-48T4S2Q |
Memory | DRAM: 2 GB |
NOR Flash | 128 MB |
NAND Flash | 1 GB |
USB | Supported |
Power supply mode | AC |
DC | |
HVDC | |
Console port | RJ45 |
Downlink Service interface | 48*10/100/1000BASE-T |
Uplink Service interface | 4*10G SFP+, 2*40G QSFP+ |
Service port supporting the stack function | 10GE optical ports and 40GE optical ports |
RTC | Supported |
Typical power consumption [W] | 92 W (50% throughput, 3 m Ethernet cables on 48 ports and high-speed cables on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) |
96 W (50% throughput, 3 m Ethernet cables on 48 ports and short-distance optical modules on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) | |
Typical heat dissipation [BTU/hour] | 314 BTU/hour (50% throughput, 3 m Ethernet cables on 48 ports and high-speed cables on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) |
327 BTU/hour (50% throughput, 3 m Ethernet cables on 48 ports and short-distance optical modules on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) | |
Static power consumption [W] | 68 W |
Static heat dissipation [BTU/hour] | 232 BTU/hour |
Maximum power consumption [W] | 137 W |
Maximum heat dissipation | 467 |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | 150 W AC power module: 100 V AC to 240 V AC, 50/60 Hz |
180 W DC power module: –48 V DC to –60 V DC | |
1200 W high-voltage DC power module: 240 V DC to 380 V DC | |
Input voltage range [V] | 150 W AC power module: 90 V AC to 290 V AC; 45 Hz to 65 Hz |
180 W DC power module: –38.4 V DC to –72 V DC | |
1200 W high-voltage DC power module: 190 V DC to 400 V DC | |
Maximum input current [A] | 150 W AC power module: 3 A (100 V AC to 240 V AC) |
180 W DC power module: 6 A (–48 V DC to –60 V DC) | |
1200 W high-voltage DC power module: 8 A | |
Rated output power [W] | 150 W AC power module: 150 W |
180 W DC power module: 180 W | |
1200 W high-voltage DC power module: 1200 W | |
Certification | Complies with safety standards. |
Complies with EMC standards. | |
Complies with environmental protection standards. | |
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode |
DC: 4 kV in common mode and 2 kV in differential mode | |
HVDC: 4 kV in common mode and 2 kV in differential mode | |
Types of fans | Pluggable |
Number of fans | 3 |
Redundant fans | The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Front-to-back or back-to-front, depending on the fan modules and power modules. |
Availability | 0.999996431 |
MTBF [year] | 57.57 years |
MTtr [hour] | 1.8 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Front-to-back airflow: 45.58 dB(A) on average (maximum: 49.2 dB(A)) |
Back-to-front airflow: 44.48 dB(A) on average (maximum: 47.6 dB(A)) | |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Front-to-back airflow: 56.91 dB(A) on average (maximum: 59.6 dB(A)) |
Back-to-front airflow: 56.94 dB(A) on average (maximum: 61.8 dB(A)) | |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.) |
Storage altitude [m (ft.)] | < 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage temperature [°C (°F)] | -40°C to +70°C (-40°F to +158°F) |
Brand | Huawei |
---|---|
CE Switch | |
Lead Time | 3-5 days |
Ship From | Shenzhen Warehouse |
Item | CE5855E-48T4S2Q |
Memory | DRAM: 2 GB |
NOR Flash | 128 MB |
NAND Flash | 1 GB |
USB | Supported |
Power supply mode | AC |
DC | |
HVDC | |
Console port | RJ45 |
Downlink Service interface | 48*10/100/1000BASE-T |
Uplink Service interface | 4*10G SFP+, 2*40G QSFP+ |
Service port supporting the stack function | 10GE optical ports and 40GE optical ports |
RTC | Supported |
Typical power consumption [W] | 92 W (50% throughput, 3 m Ethernet cables on 48 ports and high-speed cables on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) |
96 W (50% throughput, 3 m Ethernet cables on 48 ports and short-distance optical modules on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) | |
Typical heat dissipation [BTU/hour] | 314 BTU/hour (50% throughput, 3 m Ethernet cables on 48 ports and high-speed cables on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) |
327 BTU/hour (50% throughput, 3 m Ethernet cables on 48 ports and short-distance optical modules on 4 x 10G and 2 x 40G ports, normal temperature, dual AC power modules) | |
Static power consumption [W] | 68 W |
Static heat dissipation [BTU/hour] | 232 BTU/hour |
Maximum power consumption [W] | 137 W |
Maximum heat dissipation | 467 |
Number of power modules | 2 |
Redundant power supply | 1+1 backup |
Rated input voltage [V] | 150 W AC power module: 100 V AC to 240 V AC, 50/60 Hz |
180 W DC power module: –48 V DC to –60 V DC | |
1200 W high-voltage DC power module: 240 V DC to 380 V DC | |
Input voltage range [V] | 150 W AC power module: 90 V AC to 290 V AC; 45 Hz to 65 Hz |
180 W DC power module: –38.4 V DC to –72 V DC | |
1200 W high-voltage DC power module: 190 V DC to 400 V DC | |
Maximum input current [A] | 150 W AC power module: 3 A (100 V AC to 240 V AC) |
180 W DC power module: 6 A (–48 V DC to –60 V DC) | |
1200 W high-voltage DC power module: 8 A | |
Rated output power [W] | 150 W AC power module: 150 W |
180 W DC power module: 180 W | |
1200 W high-voltage DC power module: 1200 W | |
Certification | Complies with safety standards. |
Complies with EMC standards. | |
Complies with environmental protection standards. | |
Power supply surge protection [kV] | AC: 6 kV in common mode and 6 kV in differential mode |
DC: 4 kV in common mode and 2 kV in differential mode | |
HVDC: 4 kV in common mode and 2 kV in differential mode | |
Types of fans | Pluggable |
Number of fans | 3 |
Redundant fans | The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Heat dissipation mode | Air cooling |
Airflow direction | Front-to-back or back-to-front, depending on the fan modules and power modules. |
Availability | 0.999996431 |
MTBF [year] | 57.57 years |
MTtr [hour] | 1.8 hours |
Noise at normal temperature (27°C, sound pressure) [dB(A)] | Front-to-back airflow: 45.58 dB(A) on average (maximum: 49.2 dB(A)) |
Back-to-front airflow: 44.48 dB(A) on average (maximum: 47.6 dB(A)) | |
Noise at high temperature (40°C, sound pressure) [dB(A)] | Front-to-back airflow: 56.91 dB(A) on average (maximum: 59.6 dB(A)) |
Back-to-front airflow: 56.94 dB(A) on average (maximum: 61.8 dB(A)) | |
Long-term operating altitude [m (ft.)] | ≤ 5000 m (16404 ft.) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Long-term operating temperature [°C (°F)] | 0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.) |
Storage altitude [m (ft.)] | < 5000 m (16404 ft.) |
Storage relative humidity [RH] | 5% RH to 95% RH, noncondensing |
Storage temperature [°C (°F)] | -40°C to +70°C (-40°F to +158°F) |
Reviews
There are no reviews yet.