The ETP48600-C5A2 is an embedded power system that converts AC power into DC power. It supplies –48 V and –57 V constant voltage to load equipment.

Description

Overview

 

The ETP48600-C5A2 is an embedded power system that converts AC power into DC power. It supplies –48 V and –57 V constant voltage to load equipment. Its maximum power capacity is 36 kW with three-phase four-wire or three–live wire input, and 28 kW with dual–live wire or single-phase input. It can be used at newly built sites and capacity expansion and reconstruction scenarios of existing sites.

ETP48600-C5A2 Appearance

ETP48600-C5A2

 

(1) LLVD circuit breakers

(2) Power distribution label

(3) Space for the iDCDU100D1

(4) Space for the AC output module

(5) Ground screws

(6) Space for AC input module

(7) Space for rectifiers

(8) UIM05B1

(9) Space for the NIM01C3/CIM02C

(10) Battery circuit breakers

(11) SMU02C

(12) BLVD circuit breakers

ETP48600-C5A2 Datasheet

Category

ETP48600-C5A2

Specifications

Environment specifications

Operating temperature

–40°C to +65°C

(When the ambient temperature ranges from –33°C to +55°C, this product works properly. When the ambient temperature ranges from 55°C to 65°C, the output power linearly derates by 20%. When the ambient temperature is –40°C, this product starts properly after the AC power supply is connected. There is no requirement for the output voltage waveform at startup.)

Transportation temperature

–40°C to +70°C

Storage temperature

–40°C to +70°C

Operating humidity

5%–95% RH (non-condensing)

Transportation humidity

5%–95% RH (non-condensing)

Storage humidity

5%–95% RH (non-condensing)

Altitude

0–4000 m

(When the altitude ranges from 2000 m to 4000 m, the temperature condition for high temperature derating decreases by 1°C for each additional 200 m.)

Others

There is no conductive dust, corrosive gas, or explosion hazard.

Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with Class 3.1 requirements in ETSI EN 300 019-1-3 (V2.3.2 or later).

AC input

Input system

  • 220/380 V AC three-phase four-wire
  • 220 V AC three–live wire
  • 110 V AC dual–live wire, compatible with 220 V AC single-phase

Input frequency

45–66 Hz; rated value: 50 Hz/60 Hz

Power factor (PF)

≥ 0.99 (rated input voltage, 50%–100% load)

DC output

Output voltage range

  • 48 V mode: –42 V DC to –58 V DC (–53.5 V DC by default)
  • 57 V mode: –48 V DC to –57 V DC (–57 V DC by default)

Maximum output power

  • 36 kW (three-phase four-wire AC input)
  • 36 kW (three–live wire AC input)
  • 28 kW (single-phase or dual–live wire AC input)

Voltage detection precision

±0.5%

Current detection precision

  • ±1%(load current:200A~450A)
  • ±2A(load current<200A)

Regulated voltage precision

≤ ±1%

Peak-to-peak noise voltage

≤ 200 mV (0–20 MHz)

Psophometrically weighted noise voltage

≤ 2 mV (meets this standard at rated output voltage points of 53.5 V and 57 V)

Current sharing imbalance

≤ ±5% (20%–100% load)

AC input protection

AC input overvoltage protection threshold

≥ 300 V AC

AC input overvoltage recovery threshold

290–300 V AC

AC input undervoltage protection threshold

≤ 80 V AC

AC input undervoltage recovery threshold

80–90 V AC

DC output protection

DC output overvoltage protection threshold

Range: –58.5 V DC to –60.5 V DC

EMC specifications

Conducted emission

  • AC port: EN 55032, Class B
  • DC port: EN 55032, Class A1

Radiated emission

EN 55032, Class B

Harmonic current

EN 61000-3-12

Voltage fluctuation and flicker

EN 61000-3-3

ESD

IEC 61000-4-2

Enclosure port: contact discharge of 6 kV and air discharge of 8 kV; signal port: contact discharge of 2 kV

Electrical fast transient (EFT)

IEC 61000-4-4

AC/DC power port: 2 kV

Radiated susceptibility (RS)

IEC 61000-4-3

10 V/m

Conxiducted susceptibility (CS)

IEC 61000-4-6

Power port: 10 V; signal port: 3 Vxi

Surge susceptibility

IEC 61000-4-5, (criterion B)

  • AC power port: Horizontal: 6 kV (line-line), 1.2/50 μs, 2 ohms; vertical: 6 kV (single line to ground), 1.2/50 μs, 2 ohms,
  • DC power port: ±2 kV in differential mode, ±4 kV in common mode, 8/20 (1.2/50) µs
  • Signal port: Differential mode: 1.5 kV (line-line), 10/700 μs, 15 ohms+25 ohms/line; common mode: 4 kV (dual-wire or multi-wire to ground), 10/700 μs, 15 ohms+25 ohms/wire; differential mode: 1.5 kV (line-line), 1.2/50 μs, 2 ohms+40 ohms; common mode: 4 kV (dual-wire or multi-wire to ground), 1.2/50 μs, 2 ohms+n x 40 ohms/wire
  • Network port: Common mode: 4 kV (dual-wire or multi-wire to ground), 1.2/50 μs, 2 ohms+n x 40 ohms/wire

Voltage dip

Complies with IEC 61000-4-11.

Others

MTBF

200,000 hours (at 25°C)

Structure

Power system (H x W x D)

219.5 mm x 482.6 mm x 330 mm

Weight

≤ 25 kg (excluding rectifiers)

IP rating

IP20

Installation mode

Installed in a 19-inch rack

Cabling

Routed in and out from the front

Maintenance mode

Maintained from the front

Cooling mode

Free cooling

Additional information

ETP48600-C5A2 Datasheet

Category

ETP48600-C5A2

Specifications

Environment specifications

Operating temperature

–40°C to +65°C

(When the ambient temperature ranges from –33°C to +55°C, this product works properly. When the ambient temperature ranges from 55°C to 65°C, the output power linearly derates by 20%. When the ambient temperature is –40°C, this product starts properly after the AC power supply is connected. There is no requirement for the output voltage waveform at startup.)

Transportation temperature

–40°C to +70°C

Storage temperature

–40°C to +70°C

Operating humidity

5%–95% RH (non-condensing)

Transportation humidity

5%–95% RH (non-condensing)

Storage humidity

5%–95% RH (non-condensing)

Altitude

0–4000 m

(When the altitude ranges from 2000 m to 4000 m, the temperature condition for high temperature derating decreases by 1°C for each additional 200 m.)

Others

There is no conductive dust, corrosive gas, or explosion hazard.

Dust, corrosive substances, pests, molds, and other indicators should be controlled in accordance with Class 3.1 requirements in ETSI EN 300 019-1-3 (V2.3.2 or later).

AC input

Input system

  • 220/380 V AC three-phase four-wire
  • 220 V AC three–live wire
  • 110 V AC dual–live wire, compatible with 220 V AC single-phase

Input frequency

45–66 Hz; rated value: 50 Hz/60 Hz

Power factor (PF)

≥ 0.99 (rated input voltage, 50%–100% load)

DC output

Output voltage range

  • 48 V mode: –42 V DC to –58 V DC (–53.5 V DC by default)
  • 57 V mode: –48 V DC to –57 V DC (–57 V DC by default)

Maximum output power

  • 36 kW (three-phase four-wire AC input)
  • 36 kW (three–live wire AC input)
  • 28 kW (single-phase or dual–live wire AC input)

Voltage detection precision

±0.5%

Current detection precision

  • ±1%(load current:200A~450A)
  • ±2A(load current<200A)

Regulated voltage precision

≤ ±1%

Peak-to-peak noise voltage

≤ 200 mV (0–20 MHz)

Psophometrically weighted noise voltage

≤ 2 mV (meets this standard at rated output voltage points of 53.5 V and 57 V)

Current sharing imbalance

≤ ±5% (20%–100% load)

AC input protection

AC input overvoltage protection threshold

≥ 300 V AC

AC input overvoltage recovery threshold

290–300 V AC

AC input undervoltage protection threshold

≤ 80 V AC

AC input undervoltage recovery threshold

80–90 V AC

DC output protection

DC output overvoltage protection threshold

Range: –58.5 V DC to –60.5 V DC

EMC specifications

Conducted emission

  • AC port: EN 55032, Class B
  • DC port: EN 55032, Class A1

Radiated emission

EN 55032, Class B

Harmonic current

EN 61000-3-12

Voltage fluctuation and flicker

EN 61000-3-3

ESD

IEC 61000-4-2

Enclosure port: contact discharge of 6 kV and air discharge of 8 kV; signal port: contact discharge of 2 kV

Electrical fast transient (EFT)

IEC 61000-4-4

AC/DC power port: 2 kV

Radiated susceptibility (RS)

IEC 61000-4-3

10 V/m

Conxiducted susceptibility (CS)

IEC 61000-4-6

Power port: 10 V; signal port: 3 Vxi

Surge susceptibility

IEC 61000-4-5, (criterion B)

  • AC power port: Horizontal: 6 kV (line-line), 1.2/50 μs, 2 ohms; vertical: 6 kV (single line to ground), 1.2/50 μs, 2 ohms,
  • DC power port: ±2 kV in differential mode, ±4 kV in common mode, 8/20 (1.2/50) µs
  • Signal port: Differential mode: 1.5 kV (line-line), 10/700 μs, 15 ohms+25 ohms/line; common mode: 4 kV (dual-wire or multi-wire to ground), 10/700 μs, 15 ohms+25 ohms/wire; differential mode: 1.5 kV (line-line), 1.2/50 μs, 2 ohms+40 ohms; common mode: 4 kV (dual-wire or multi-wire to ground), 1.2/50 μs, 2 ohms+n x 40 ohms/wire
  • Network port: Common mode: 4 kV (dual-wire or multi-wire to ground), 1.2/50 μs, 2 ohms+n x 40 ohms/wire

Voltage dip

Complies with IEC 61000-4-11.

Others

MTBF

200,000 hours (at 25°C)

Structure

Power system (H x W x D)

219.5 mm x 482.6 mm x 330 mm

Weight

≤ 25 kg (excluding rectifiers)

IP rating

IP20

Installation mode

Installed in a 19-inch rack

Cabling

Routed in and out from the front

Maintenance mode

Maintained from the front

Cooling mode

Free cooling