S3352P-EI-24S-DC

S3352P-EI-24S-DC

Huawei S3352P-EI-24S-DC switch supports 24 10/100BASE-T ports, 24 10/100BASE-X ports, 2 10/100/1000BASE-X ports, 2 10/100/1000BASE-X ports, fixed DC power

Huawei

3-5 days

Shenzhen Warehouse

SKU: 5615 PN: 02351422 Category: Tags: , ,

Description

Item S3352P-EI-24S-DC
Fixed port 24 10/100Base-TX ports, 24 100 BASE-X ports, 2 100/1000 BASE-X ports, 2 1000 BASE-X ports
Processor Dominant frequency: 200 MHz
Switching capacity 17.6 Gbit/s
Forwarding performance 13.1 Mpps
DDR memory 128 MB
Flash Memory 16 MB
Backplane switching capacity 64 Gbit/s
MAC address table Supports 8 K MAC address entries.
Supports manual addition and deletion of a MAC address table.
Supports configuration of MAC address aging time.
Supports disabling of MAC address learning based on port or aggregation group.
Supports limit on the number of MAC addresses to be learned on a port.
Supports blackhole MAC addresses.
VLAN features Supports IEEE 802.1Q (VLAN) and 4096 VLANs.
Supports port-based VLAN.
Supports MAC-based VLAN.
Supports basic QinQ.
Supports 1:1 VLAN switching.
Supports N:1 VLAN switching.
QoS/ACL Supports rate limit on packets sent and received by a port.
Supports packet redirection.
Supports port-based traffic policing and two-rate three-color CAR.
Supports multiple queue scheduling algorithms including WRR, DRR, SP, WRR+SP, and DRR+SP.
Supports re-marking of the 802.1p priority and DSCP priority.
Supports packet filtering based on Layer 2 to Layer 4 information, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, port number, protocol, and VLAN ID.
Supports queue-based rate limit and traffic shaping on ports.
Supports traffic-based priority marking and packet redirection.
IPv6 features Supports PMTU.
Supports Neighbor Discovery (ND).
Supports IPv6 Ping, IPv6 Tracert, and IPv6 Telnet.
Supports manually configured tunnels.
Supports 6-to-4 tunnels.
Supports ISATAP tunnels.
Supports ACLs based on the source IPv6 address, destination IPv6 address, Layer-4 port,or protocol type.
Supports MLD v1/v2 snooping.
Multicast Supports 1024 multicast groups.
Supports IGMP v1/v2/v3 snooping and fast leave.
Supports multicast VLAN and cross-VLAN multi cast replication.
Supports multicast load sharing among bundled ports.
Supports controllable multicast.
Supports port-based multicast traffic statistics.
Supports IGMP v1/v2/v3, PIM-SM, and PIM-DM.
Security Supports hierarchical user management and password protection.
Supports DoS attack defense, ARP attack defense, and ICMP attack defense.
Supports binding of the IP address, MAC address, port number, and VLAN ID.
Supports port isolation, port security, and sticky MAC.
Supports blackhole MAC addresses.
Supports limit on the number of MAC addresses to be learned.
Supports IEEE 802.1X authentication and the limit on the maximum number of users on a port.
Supports multiple authentication methods including AAA, RADIUS, HWTACACS+, and NAC.
Supports SSH v2.
Supports CPU protection.
Supports blacklisting and whitelisting.
Surge protection Each port has a surge protection capability of 6 KV. Each port has a surge protection capability of 15 KV after an extra surge protection device is added.
Management and maintenance Supports iStack (except the S33HI).
Supports MAC Forced Forwarding (MFF).
Supports auto-config and HGMP.
Supports remote configuration and maintenance by using Telnet.
Supports Virtual Cable Test (VCT).
Supports Ethernet OAM (IEEE 802.3ah and 802.1ag).
Supports Dying gasp power-off alarm (the S3328TP-EI-MC and the S3326C-HI only).
Supports local port mirroring, Remote Switched Port Analyzer (RSPAN), and packet forwarding on an observing port.
Supports SNMP v1/v2/v3 and RMON.
Supports MUX VLAN and GVRP.
Supports the Network Management System (NMS) and Web management.
Supports SSH v2.
Supports HTTPS (the S3300HI only).
Supports 802.3az EEE (the S3300HI only).
Supports system logs and multi-level alarms.
Operating environment Operating temperature: 0°C to 50°C (long term); –5°C to 55°C (short term);
Relative humidity: 10% to 90% (non-condensing)
Power supply DC:
Rated voltage: –48 V to –60 V
Maximum voltage: –36 V to –72 V
Note: Models supporting PoE do not use DC power supplies.
Dimensions (mm) 442 (W) x 420 (D)x 43.6 (H)
Weight < 2.6 kg
Power consumption < 66 W

Additional information

Weight 8.5000 kg
Dimensions 57.7000 × 59.0000 × 12.0000 cm

Reviews

There are no reviews yet.


Be the first to review “S3352P-EI-24S-DC”

has been added to your cart:
Checkout