Huawei OptiX OSN 9800 TNV1T601 1*400GE Tributary Service Processing Board

Description

TNV1T601 overview

 

TNV1T601 1*400GE Tributary Service Processing Board applied to Huawei OptiX OSN 9800 U64/U32/M24.

To meet ultra-large cross-connect capacity and bandwidth requirements, Huawei presents the OptiX OSN 9800 product series. The OptiX OSN 9800 product series include the OptiX OSN 9800 U64, U32, P18 and universal platform subracks. Applied at the electrical layer, the OptiX OSN 9800 U64 and U32 subracks share boards by using unified software and hardware platforms, and can work with the OptiX OSN 9800 universal platform subrack and P18 subrack, OptiX OSN 8800 platform subrack and T16 subrack, and OptiX OSN 6800 optical subracks in WDM and OTN systems.

The TNV1T601 board has only one variant: TNV1T601C01.

 

 

Front panel of the TNV1T601 board

TNV1T601

 

 

Front panel of the TNV1T601 board

 

Valid slots for the TNV1T601 board in a U64/U32/M24 subrack

Device Number of Occupied Slots Physical Slot Logical Slot
OptiX OSN 9800 M24 2 (IU1, IU13), (IU2, IU14), ……, (IU11, IU23), (IU12, IU24) IU1 to IU12
OptiX OSN 9800 U32 Enhanced 1 IU1 to IU32 IU1 to IU32
OptiX OSN 9800 U32 Standard 1 IU1 to IU32 IU1 to IU32
OptiX OSN 9800 U64 Enhanced 1 IU1 to IU64 IU1 to IU64
OptiX OSN 9800 U64 Standard 1 IU1 to IU64 IU1 to IU64

 

Item TNV1T601
Backplane capacity The total bandwidth is 400 Gbit/s.
NOTE:
Supports backplane cross-connections of four ODUflex signals from/to the cross-connect board.
Client-side service type 400GE: Ethernet service at a rate of 425 Gbit/s.
Service mapping mode 400GE (Bit Transparent Mapping)
FEC coding RSFEC
OTN overhead Provides PM for ODUflex.
NOTE:
Supports overhead processing defined by ITU-T G.709. The service mapping process complies with ITU-T G.709 and G.Sup43.
LPT Not supported
Client 1+1 protection Not supported
ODUk SNCP Supported
NOTE:
After multiple ODUK SNCP protection groups are created for the T601 board, the protection groups must be bound to implement unified switching of multiple ODUK SNCP protection groups.
Tributary SNCP Not supported
Electrical-layer ASON Supported
L1 service encryption Supported
ALS Supported
LLDP Supported
Physical clock Not supported
IEEE 1588v2 Not supported
ITU-T G.8275.1 Not supported
ITU-T G.8273.2 Not supported
Outband DCN Not supported
Test frame Supported
PRBS Supported the PRBS function in the backplane direction.
Latency measurement Supports the latency measurement of the PM section in the backplane direction (upstream direction).
Channel loopback Supports inloops and outloops on channels.
Port loopback Supports inloops and outloops on the client side.
Alarm and performance event monitoring
  • Monitors BIP8 bytes to help locate line failures.
  • Monitors parameters such as the bias current, temperature, and optical power of the laser.
  • Provides remote monitoring (RMON) of the Ethernet service.
Dimensions (H x W x D)
  • 477.30 × 30.50 × 220.00 (mm)
  • 18.81 × 1.20 × 8.67 (in.)
Weight
  • 2.50 kg
  • 5.51 lb.

Additional information

Brand
Lead Time
Ship From
Warranty
Condition
Item TNV1T601
Backplane capacity The total bandwidth is 400 Gbit/s.
NOTE:
Supports backplane cross-connections of four ODUflex signals from/to the cross-connect board.
Client-side service type 400GE: Ethernet service at a rate of 425 Gbit/s.
Service mapping mode 400GE (Bit Transparent Mapping)
FEC coding RSFEC
OTN overhead Provides PM for ODUflex.
NOTE:
Supports overhead processing defined by ITU-T G.709. The service mapping process complies with ITU-T G.709 and G.Sup43.
LPT Not supported
Client 1+1 protection Not supported
ODUk SNCP Supported
NOTE:
After multiple ODUK SNCP protection groups are created for the T601 board, the protection groups must be bound to implement unified switching of multiple ODUK SNCP protection groups.
Tributary SNCP Not supported
Electrical-layer ASON Supported
L1 service encryption Supported
ALS Supported
LLDP Supported
Physical clock Not supported
IEEE 1588v2 Not supported
ITU-T G.8275.1 Not supported
ITU-T G.8273.2 Not supported
Outband DCN Not supported
Test frame Supported
PRBS Supported the PRBS function in the backplane direction.
Latency measurement Supports the latency measurement of the PM section in the backplane direction (upstream direction).
Channel loopback Supports inloops and outloops on channels.
Port loopback Supports inloops and outloops on the client side.
Alarm and performance event monitoring
  • Monitors BIP8 bytes to help locate line failures.
  • Monitors parameters such as the bias current, temperature, and optical power of the laser.
  • Provides remote monitoring (RMON) of the Ethernet service.
Dimensions (H x W x D)
  • 477.30 × 30.50 × 220.00 (mm)
  • 18.81 × 1.20 × 8.67 (in.)
Weight
  • 2.50 kg
  • 5.51 lb.

Reviews

There are no reviews yet.

Be the first to review “TNV1T601”

Your email address will not be published. Required fields are marked *

TNV1T601

0 Reviews Write a review
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

Huawei OptiX OSN 9800 OTN Tributary Board TNV1T601

Description

TNV1T601 overview

This topic describes the substitution relationship between OTN tributary boards.

Unless otherwise specified, a substitute board can be created as the logical board of the original board on the NMS and substitutes for the original board. The board substitution does not require any software upgrade. After the board substitution, the substitute board has only the functions of the original board.

Original Board Substitute Board Using the Version Replacement Function Substitution Rule
TNV1T601 TNV2T601
  • During board substitution using the version replacement function, the NE where the original board resides does not need to be upgraded.
  • The substitute board can be created as the logical board of the original board on the NMS and replace the original board. The substitute board has only the functions of the original board.
  • During board substitution using the version replacement function, because the original board and substitute board support the same optical modules, the optical modules of the original board can still be used.
  • Only when working with the U2CTU/U4CTU/U5CTU/G1CXP/G3CXP/G4CXP board, a TNV2T601 board can substitute for a TNV1T601 board using the version replacement function.

Optical module substitution

Original Optical Module Substitute Optical Module Substitution Rule
CFP8,8*56Gb/s PAM4(1310nm),425Gb/s,-2.8dBm,5.3dBm,-9.1dBm,LC,ITU-T G.652(SMF),10km QSFP-DD LR8,8*50Gb/s PAM4(1310nm Band),425Gb/s,-2.8dbm,5.3dbmm,-9.1dbm,LC straight,SMF,10km N/A
Substitution Relationship between 10G OTN Tributary Boards
Original Board Substitute Board Using the Version Replacement Function Substitution Rule
TNV1T130 TNV3T230 For details about board substitution, see the general description.
TNV1T210 TNV3T230 When a TNV3T230 board substitutes for a TNV1T210 board by using the version replacement function, only ports TX1/RX1 to TX10/RX10 can be used.
TNV2T210 TNV3T210 For details about board substitution, see the general description.
TNV2T210 TNV3T230 When a TNV3T230 board substitutes for a TNV2T210 board by using the version replacement function, only ports TX1/RX1 to TX10/RX10 can be used.
TNV2T220 TNV3T230 When a TNV3T230 board substitutes for a TNV2T220 board by using the version replacement function, only ports TX1/RX1 to TX20/RX20 can be used.
TNV2T220 TNV7T220
  • When a TNV7T220 board substitutes for a TNV2T220 board using the version replacement function, only the TNU2UXCS/TNS1UXCS cross-connect board is supported.
  • The power consumption of the TNV7T220 board is higher than that of the TNV2T220 board. To use a TNV7T220 board to substitute for a TNV2T220 board, ensure that the subrack power supply has a sufficient margin. If the nominal power consumption of the TNV7T220 board exceeds the available power supply capability of the subrack, the TNV7T220 board will not be powered on, and the logical board and related services cannot be created. As a result, the board substitution fails.
TNV3T220 TNV7T220
  • When a TNV7T220 board substitutes for a TNV3T220 board using the version replacement function, only the TX11/RX11 to TX14/RX14 ports can be used to receive FC1600 services.
  • The power consumption of the TNV7T220 board is higher than that of the TNV3T220 board. To use a TNV7T220 board to substitute for a TNV3T220 board, ensure that the subrack power supply has a sufficient margin. If the nominal power consumption of the TNV7T220 board exceeds the available power supply capability of the subrack, the TNV7T220 board will not be powered on, and the logical board and related services cannot be created. As a result, the board substitution fails.
  • When a TNV7T220 board substitutes for a TNV3T220 board using the version replacement function, the Service Type is set to Any in ODU1 convergence mode, the TNV7T220 board does not support end-to-end client-side interconnection with the peer TNV3T210/TNV3T220/TNV3T230/TNG1T206/TNG1T212/TNG1A212/TNG2A212/TNG1M210D board.
TNV1T216 TNV3T230 When a TNV3T230 board substitutes for a TNV1T216 board by using the version replacement function, only ports TX1/RX1 to TX16/RX16 can be used.
TNV6T220 TNV7T220
  • The power consumption of the TNV7T220 board is higher than that of the TNV6T220 board. To use a TNV7T220 board to substitute for a TNV6T220 board, ensure that the subrack power supply has a sufficient margin. If the nominal power consumption of the TNV7T220 board exceeds the available power supply capability of the subrack, the TNV7T220 board will not be powered on, and the logical board and related services cannot be created. As a result, the board substitution fails.
  • When a TNV7T220 board substitutes for a TNV6T220 board using the version replacement function, the Service Type is set to Any in ODU1 convergence mode, the TNV7T220 board does not support end-to-end client-side interconnection with the peer TNV3T210/TNV3T220/TNV3T230/TNG1T206/TNG1T212/TNG1A212/TNG2A212/TNG1M210D board.
Substitution Relationship between 100G and beyond-100G OTN Tributary Boards
Original Board Substitute Board Using the Version Replacement Function
TNV1T401 TNV3T401
TNV1T402 TNV3T402
TNV1T402 TNU1G402
TNV5T402 TNV8T402
TNV7T402 TNV8T402
TNV2T404 TNV3T404
TNV2T404 TNV5T404
TNV2T404 TNV8T404
TNV2T404 TNU1G404
TNV3T404 TNV5T404
TNV3T404 TNV8T404
TNV5T404 TNV8T404
TNV1T402/TNV3T402 TNV1T502
TNV1T601 TNV2T601

Additional information

Brand

Huawei

Lead Time

3-5 days

Ship From

Shenzhen Warehouse

Substitution Relationship between 10G OTN Tributary Boards
Original Board Substitute Board Using the Version Replacement Function Substitution Rule
TNV1T130 TNV3T230 For details about board substitution, see the general description.
TNV1T210 TNV3T230 When a TNV3T230 board substitutes for a TNV1T210 board by using the version replacement function, only ports TX1/RX1 to TX10/RX10 can be used.
TNV2T210 TNV3T210 For details about board substitution, see the general description.
TNV2T210 TNV3T230 When a TNV3T230 board substitutes for a TNV2T210 board by using the version replacement function, only ports TX1/RX1 to TX10/RX10 can be used.
TNV2T220 TNV3T230 When a TNV3T230 board substitutes for a TNV2T220 board by using the version replacement function, only ports TX1/RX1 to TX20/RX20 can be used.
TNV2T220 TNV7T220
  • When a TNV7T220 board substitutes for a TNV2T220 board using the version replacement function, only the TNU2UXCS/TNS1UXCS cross-connect board is supported.
  • The power consumption of the TNV7T220 board is higher than that of the TNV2T220 board. To use a TNV7T220 board to substitute for a TNV2T220 board, ensure that the subrack power supply has a sufficient margin. If the nominal power consumption of the TNV7T220 board exceeds the available power supply capability of the subrack, the TNV7T220 board will not be powered on, and the logical board and related services cannot be created. As a result, the board substitution fails.
TNV3T220 TNV7T220
  • When a TNV7T220 board substitutes for a TNV3T220 board using the version replacement function, only the TX11/RX11 to TX14/RX14 ports can be used to receive FC1600 services.
  • The power consumption of the TNV7T220 board is higher than that of the TNV3T220 board. To use a TNV7T220 board to substitute for a TNV3T220 board, ensure that the subrack power supply has a sufficient margin. If the nominal power consumption of the TNV7T220 board exceeds the available power supply capability of the subrack, the TNV7T220 board will not be powered on, and the logical board and related services cannot be created. As a result, the board substitution fails.
  • When a TNV7T220 board substitutes for a TNV3T220 board using the version replacement function, the Service Type is set to Any in ODU1 convergence mode, the TNV7T220 board does not support end-to-end client-side interconnection with the peer TNV3T210/TNV3T220/TNV3T230/TNG1T206/TNG1T212/TNG1A212/TNG2A212/TNG1M210D board.
TNV1T216 TNV3T230 When a TNV3T230 board substitutes for a TNV1T216 board by using the version replacement function, only ports TX1/RX1 to TX16/RX16 can be used.
TNV6T220 TNV7T220
  • The power consumption of the TNV7T220 board is higher than that of the TNV6T220 board. To use a TNV7T220 board to substitute for a TNV6T220 board, ensure that the subrack power supply has a sufficient margin. If the nominal power consumption of the TNV7T220 board exceeds the available power supply capability of the subrack, the TNV7T220 board will not be powered on, and the logical board and related services cannot be created. As a result, the board substitution fails.
  • When a TNV7T220 board substitutes for a TNV6T220 board using the version replacement function, the Service Type is set to Any in ODU1 convergence mode, the TNV7T220 board does not support end-to-end client-side interconnection with the peer TNV3T210/TNV3T220/TNV3T230/TNG1T206/TNG1T212/TNG1A212/TNG2A212/TNG1M210D board.
Substitution Relationship between 100G and beyond-100G OTN Tributary Boards
Original Board Substitute Board Using the Version Replacement Function
TNV1T401 TNV3T401
TNV1T402 TNV3T402
TNV1T402 TNU1G402
TNV5T402 TNV8T402
TNV7T402 TNV8T402
TNV2T404 TNV3T404
TNV2T404 TNV5T404
TNV2T404 TNV8T404
TNV2T404 TNU1G404
TNV3T404 TNV5T404
TNV3T404 TNV8T404
TNV5T404 TNV8T404
TNV1T402/TNV3T402 TNV1T502
TNV1T601 TNV2T601