ZXR10 M6000-16

0 Reviews Write a review
SKU2009533
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

ZXR10 M6000-16 supports 2*MPU Control Board,4*SFU Switch Board,16*PFU, 2*AC/DC Power Module

Description

Overview

The ZXR10 M6000 is a series of large-capacity, high-performance, and carrier-class high-end core routers and integrated multi-service gateway devices. It is developed by ZTE on the base of development experiences of high-end core routers, SRs, and BRASs, and deep understanding about the service-edge control plane on carriers’ networks.

The ZXR10 M6000 series routers are new-generation Broadband Multi-Service Gateway (BMSG) products with large capacity and high performance. This series of routers are designed for carriers’ backbone networks, Metropolitan Area Networks (MANs), mobile bearer networks, Internet Data Centers (IDC), government networks and enterprise networks.

The ZXR10 M6000 series products include ZXR10 M6000-16 and ZXR10 M6000-8.

ZXR10 M6000 series routers can be used on networks of different scales.
  • On MANs: used as high-end SRs, large-capacity BRASs/BMSGs and IPRAN core routers.
  • On enterprise networks: used as core routers, egress routers and vertical backbone nodes.
  • On backbone bearer MANs: used as core service control/service gateway nodes.
Features
  • Network Availability
  • Unicast Routing Protocols
  • MPLS and VPN Service
  • IPv4 and IPv6 Features
  • Broadband User Access
  • Accurate User Positioning Technology
  • BRAS Hot Standby
  • User and Service Management
  • Clock Synchronization
Item ZXR10 M6000-16
Heat dissipation system Vertical fan modules 0
Horizontal fan modules 2
Fans in each vertical fan module None
Fans in each horizontal fan module 9
Redundancy backup mode 1+1
Speed-change mode Support
Heat dissipation 26559 BTU/hour
Environmental requirement (operation) Temperature -5 ℃ - 45 ℃
Humidity 5% - 90%
Altitude < 5470.46 yd. (5000 m) (refer to the following note)
Environmental requirement (storage) Temperature -40 ℃ - +70 ℃
Humidity 0 - 95%
Altitude ≤ 5470.46 yd. (5000 m) (refer to the following note)
DC Redundancy backup 1+1
Rated power consumption of the whole device 5300 W
Rated voltage -48 V
Maximum voltage range -60 V - -40 V
Rated input current
75 A/area
Air circuit breaker (recommended)
100 A × 4 (full configuration, providing power to Area 2)
AC Redundancy backup 4+4
Rated power consumption of the whole device 5300 W
Rated input voltage 200 V - 240 V
Input frequency range 50 Hz / 60 Hz
Rated output voltage -53.5 V
Rated output current NA
Rectifier module rated output power 2000 W/module
Air circuit breaker (recommended) 63 A × 2 (full configuration, providing power to Area 2)
Weight Cabinet (with backboard) 141.09 lb. (64 kg)
Full configuration 529.1 lb. (240 kg)
Slots Total slots 22
MPU slots 2
SFU slots 4
PFU slots 16
Earthing resistance Resistance for joint grounding: < 5 Ω
Dimensions (H × W × D) 66.43 in. × 17.41 in. × 23.64 in. (1686 mm × 442 mm × 600 mm)

Additional information

Brand

ZTE

Lead Time

3-5 days

Ship From

Shenzhen Warehouse

Item ZXR10 M6000-16
Heat dissipation system Vertical fan modules 0
Horizontal fan modules 2
Fans in each vertical fan module None
Fans in each horizontal fan module 9
Redundancy backup mode 1+1
Speed-change mode Support
Heat dissipation 26559 BTU/hour
Environmental requirement (operation) Temperature -5 ℃ - 45 ℃
Humidity 5% - 90%
Altitude < 5470.46 yd. (5000 m) (refer to the following note)
Environmental requirement (storage) Temperature -40 ℃ - +70 ℃
Humidity 0 - 95%
Altitude ≤ 5470.46 yd. (5000 m) (refer to the following note)
DC Redundancy backup 1+1
Rated power consumption of the whole device 5300 W
Rated voltage -48 V
Maximum voltage range -60 V - -40 V
Rated input current
75 A/area
Air circuit breaker (recommended)
100 A × 4 (full configuration, providing power to Area 2)
AC Redundancy backup 4+4
Rated power consumption of the whole device 5300 W
Rated input voltage 200 V - 240 V
Input frequency range 50 Hz / 60 Hz
Rated output voltage -53.5 V
Rated output current NA
Rectifier module rated output power 2000 W/module
Air circuit breaker (recommended) 63 A × 2 (full configuration, providing power to Area 2)
Weight Cabinet (with backboard) 141.09 lb. (64 kg)
Full configuration 529.1 lb. (240 kg)
Slots Total slots 22
MPU slots 2
SFU slots 4
PFU slots 16
Earthing resistance Resistance for joint grounding: < 5 Ω
Dimensions (H × W × D) 66.43 in. × 17.41 in. × 23.64 in. (1686 mm × 442 mm × 600 mm)

Reviews

There are no reviews yet.

Be the first to review “ZXR10 M6000-16”

Your email address will not be published. Required fields are marked *

Back to Top

Search For Products

Product has been added to your cart