OptiX OSN 1800 V

2 Reviews Write a review
SKU2011514
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

The OptiX OSN 1800 V is an enhanced 5U packet chassis of high integration.

Description

An OSN 1800 V chassis can be AC or DC powered. The DC powered chassis uses the PIU board and the AC powered chassis uses the APIU board. In the AC powered chassis, the APIU board occupies two slots.

 

Highlights of OSN 1800 V Packet Enhanced

  • MS-OTN compliance and compact design (5 U high), supporting access of Any-rate services

    • A single chassis supports full-granularity cross-connections and multiplexing (only Z-series cross-connections support ODU3). It allows for a maximum of 700 Gbit/s OTN capacity, 700 Gbit/s packet capacity, 280 Gbit/s SDH higher-order and 40 Gbit/s SDH lower-order capacities, and supports ODUk (k = 0, 1, 2, 2e, 3, 4, C2, flex). This significantly improves line bandwidth usage.
    • The 1800 V supports universal line boards, allowing services after being scheduled on the OTN, SDH, PKT service planes to hitlessly share line transmission bandwidth.
    • Being highly integrated, each 1800 V chassis is 5 U high and provides a maximum of 15 service slots.
    • Targeted for metro edge applications, the 1800 V can be deployed as a service access or aggregation node, and supports uniform of full services (1.5 Mbit/s to 100 Gbit/s).
  • Environment friendly, power saving, and easy to deploy and maintain

    • Supports power saving and consumes low power in a typical configuration, reducing OPEX for customers.
    • Easy to deploy, supports installation in a 19-inch or ETSI cabinet and AC and DC power supplies.
    • Supports OTN inband management compliant with ITU-T G.709.
  • Distinguished architecture, high reliability, and secure data transmission

    • Provides various network-level protection schemes for all-around service protection.
    • Provides equipment-level protection: power supply protection, fan protection, and 1+1 protection for system control, cross-connect, and clock integrated boards.
  • Built-in pulse code modulation (PCM) provides an all-in-one solution to satisfy enterprise customers’ requirements on low-speed service access. Built-in PCM has the following features:

    • Reduces types of devices, delayering the network.
    • Operates on a universal transmission platform, facilitating network expansion and evolution.
    • Supports fast fault locating using the unified NMS.

 

Slot layout of the chassis (DC powered)

Slot layout of the chassis DC powered 1

 

Slot layout of the chassis (AC powered)

Slot layout of the chassis AC powered 1

 

Equipment Capacity

OptiX OSN equipment has high service access capacity and supports flexible grooming of electrical layer signals at service aggregation nodes.

OSN 1800 equipment supports MS-OTN-based universal service grooming. According to the planned chassis capability, a single chassis supports a maximum of 700 Gbit/s OTN capacity, 700 Gbit/s packet capacity, 280 Gbit/s SDH higher-order and 40 Gbit/s SDH lower-order capacities.

Slot capacity

 

Item

OptiX OSN 1800 V

Mounting option

  • 19-inch cabinet
  • ETSI 300mm deep cabinet, such as A63B, N63B
  • Mini Shelter cabinet

Number of slots for service boards

  • DC-powered chassis: 15
  • AC-powered chassis: 12

Optical switching capability

1 to 9-degree ROADM

Electrical switching capacity

OTN

700 Gbit/s

Packet service

700 Gbit/s

TDM

Higher order: 280 Gbit/s; lower order: 40 Gbit/s

Maximum number of wavelengths

DWDM

80 wavelengths

CWDM

8 wavelengths

Center wavelength range

  • DWDM: 1529.16 nm to 1560.61 nm (C Band, ITU-T G.694.1)
  • CWDM: 1471 nm to 1611 nm (S+C+L Band, ITU-T G.694.2)

Service types

SDH/SONET service, PDH service, OTN service, Ethernet service, PCM service, CPRI service, OBSAI service, SAN service, video service, and others

Maximum rate per channel

200 Gbit/s

Line rate

2.5 Gbit/s, 10 Gbit/s, 50Gbit/s, 100 Gbit/s, 200 Gbit/s

Maximum total of OSN 810 and OSN 850 devices managed by each OSN 1800 NE

50

NOTE:

The quantity depends on the number of C12X5&C15Xn boards and the boards interconnected with the OSN 850 devices which are inserted in the OSN 1800 NE

Pluggable optical/electrical module

  • Optical module: SFP/eSFP, XFP, SFP+, QSFP+, TXFP, CFP, CFP2, QSFP28
  • Electrical module: GE SFP, FE SFP, STM-1 SFP

Topology

Point-to-point, chain, star, ring, ring-with-chain, intersecting rings, tangent rings, and mesh networking

Network level protection (OTN)

Client 1+1 protection, intra-board 1+1 protection, ODUk SNCP, optical line protection, tributary SNCP, and LPT

Network level protection (packet)

Tunnel APS, PW APS/FPS, MC-PW APS, MC-LAG, LPT, LAG, ERPS, MRPS, LMSP, packet SNCP

Network level protection (TDM)

  • SDH protection: SNCP, linear MSP, ring MSP, TPS, SNCTP
  • EoS protection: LAG, DLAG, LCAS, LPT, BPS, and STP/RSTP
  • PCM protection: E1 SNCP, 64K SNCP, Hitless protection switching

Equipment level protection

  • Control, cross-connect, and clock integrated board redundancy
  • Power supply redundancy

  • Fan redundancy

Optical power management

ALS, AGC, OPA, IPA

Maintenance

  • MPLS-TP OAM
  • ETH OAM
  • Port mirroring
  • Port traffic mirroring (packet)
  • Loopback
  • PRBS
  • LLDP

Easy O&M

Optical Doctor System, Fiber Doctor System

Synchronization

  • Physical Clocks (OTN & Packet & SDH)
  • IEEE 1588v2 (OTN & Packet)
  • ITU-T G.8275.1/G.8273.2 (OTN & Packet)

ASON

OTN network: Electrical-Layer ASON and Optical-Layer ASON (only Z-series cross-connections support).

OCS network: SDH ASON (Z5UXCMS, Z5XCS)

OCS network: 2M ASON (Z5UXCM, Z5XCS)

Power supply

DC power input
  • Standard working voltage: -48V to -60V
  • Working voltage range: -40V to -72V
AC power input
  • Standard working voltage: 100V AC to 120V AC, and 200V AC to 240V AC

Running environment

Chassis temperature

  • Long-term running: -5°C to +50°C
  • Short-terma running: -10°C to +55°C

Chassis relative humidity

  • Long-term running: 5% to 85%
  • Short-term running: 5% to 95%

ETSI conformity

ETSI Class 3.1

NOTE:

ETSI standards define temperature and humidity environments, where equipment is located.

Reliability Specifications

MTTR (system mean repair time)

4 hours

MTBF (system mean fault interval)

129.63 years

Dimensions (H x D x W)

221 mm x 220 mm x 442 mm (excluding the handle)

Weight (empty chassis)

8.0 kg (17.6 lb.)

Additional information

Brand

Huawei

Item

OptiX OSN 1800 V

Mounting option

  • 19-inch cabinet
  • ETSI 300mm deep cabinet, such as A63B, N63B
  • Mini Shelter cabinet

Number of slots for service boards

  • DC-powered chassis: 15
  • AC-powered chassis: 12

Optical switching capability

1 to 9-degree ROADM

Electrical switching capacity

OTN

700 Gbit/s

Packet service

700 Gbit/s

TDM

Higher order: 280 Gbit/s; lower order: 40 Gbit/s

Maximum number of wavelengths

DWDM

80 wavelengths

CWDM

8 wavelengths

Center wavelength range

  • DWDM: 1529.16 nm to 1560.61 nm (C Band, ITU-T G.694.1)
  • CWDM: 1471 nm to 1611 nm (S+C+L Band, ITU-T G.694.2)

Service types

SDH/SONET service, PDH service, OTN service, Ethernet service, PCM service, CPRI service, OBSAI service, SAN service, video service, and others

Maximum rate per channel

200 Gbit/s

Line rate

2.5 Gbit/s, 10 Gbit/s, 50Gbit/s, 100 Gbit/s, 200 Gbit/s

Maximum total of OSN 810 and OSN 850 devices managed by each OSN 1800 NE

50

NOTE:

The quantity depends on the number of C12X5&C15Xn boards and the boards interconnected with the OSN 850 devices which are inserted in the OSN 1800 NE

Pluggable optical/electrical module

  • Optical module: SFP/eSFP, XFP, SFP+, QSFP+, TXFP, CFP, CFP2, QSFP28
  • Electrical module: GE SFP, FE SFP, STM-1 SFP

Topology

Point-to-point, chain, star, ring, ring-with-chain, intersecting rings, tangent rings, and mesh networking

Network level protection (OTN)

Client 1+1 protection, intra-board 1+1 protection, ODUk SNCP, optical line protection, tributary SNCP, and LPT

Network level protection (packet)

Tunnel APS, PW APS/FPS, MC-PW APS, MC-LAG, LPT, LAG, ERPS, MRPS, LMSP, packet SNCP

Network level protection (TDM)

  • SDH protection: SNCP, linear MSP, ring MSP, TPS, SNCTP
  • EoS protection: LAG, DLAG, LCAS, LPT, BPS, and STP/RSTP
  • PCM protection: E1 SNCP, 64K SNCP, Hitless protection switching

Equipment level protection

  • Control, cross-connect, and clock integrated board redundancy
  • Power supply redundancy

  • Fan redundancy

Optical power management

ALS, AGC, OPA, IPA

Maintenance

  • MPLS-TP OAM
  • ETH OAM
  • Port mirroring
  • Port traffic mirroring (packet)
  • Loopback
  • PRBS
  • LLDP

Easy O&M

Optical Doctor System, Fiber Doctor System

Synchronization

  • Physical Clocks (OTN & Packet & SDH)
  • IEEE 1588v2 (OTN & Packet)
  • ITU-T G.8275.1/G.8273.2 (OTN & Packet)

ASON

OTN network: Electrical-Layer ASON and Optical-Layer ASON (only Z-series cross-connections support).

OCS network: SDH ASON (Z5UXCMS, Z5XCS)

OCS network: 2M ASON (Z5UXCM, Z5XCS)

Power supply

DC power input
  • Standard working voltage: -48V to -60V
  • Working voltage range: -40V to -72V
AC power input
  • Standard working voltage: 100V AC to 120V AC, and 200V AC to 240V AC

Running environment

Chassis temperature

  • Long-term running: -5°C to +50°C
  • Short-terma running: -10°C to +55°C

Chassis relative humidity

  • Long-term running: 5% to 85%
  • Short-term running: 5% to 95%

ETSI conformity

ETSI Class 3.1

NOTE:

ETSI standards define temperature and humidity environments, where equipment is located.

Reliability Specifications

MTTR (system mean repair time)

4 hours

MTBF (system mean fault interval)

129.63 years

Dimensions (H x D x W)

221 mm x 220 mm x 442 mm (excluding the handle)

Weight (empty chassis)

8.0 kg (17.6 lb.)

Reviews

  1. Joaquín

    OptiX OSN 1800 V is a brand new model, i like to purchase equipments here.

  2. Roger

    I sent demands to their sales team, and they completed the quotation very quickly, very professional.

Add a review

Your email address will not be published. Required fields are marked *

Back to Top

Search For Products

Product has been added to your cart