Description
PAC1K2S12-PB Overview
Huawei PAC1K2S12-PB with 1200W AC&240V DC Power Module (Back to Front,Power panel side exhaust) apply to CloudEngine XH9000 and XH8000 Series Switches.
Mappings between PAC1K2S12-PB and product models
Product | Product Model | First Supported Version |
---|---|---|
CloudEngine XH8000 | XH8110-24BQ8DQ (02355YSK) | V300R023C10 |
CloudEngine XH8000 | XH8110-24BQ8DQ (02355YSL) | V300R023C10 |
CloudEngine XH8000 | XH8110-24BQ8DQ (02355YSJ) | V300R023C10 |
CloudEngine XH9000 | XH9110-24BQ8DQ (02355YSP) | V300R023C10 |
CloudEngine XH9000 | XH9110-24BQ8DQ (02355YSM) | V300R023C10 |
CloudEngine XH9000 | XH9110-24BQ8DQ (02355YSN) | V300R023C10 |
Front Panel
1. Handle | 2. Airflow flag | 3. Air vent | 4. Indicator |
5. Power socket |
6. Lock |
– |
– |
Functions of the PAC1K2S12-PB
Functions | Description |
---|---|
Input overvoltage protection and undervoltage protection | In this protection state, the power module stops supplying power. When the input voltage restores to the normal range, the power module automatically resumes power supply. |
Input overcurrent protection | In this protection state, the power module stops supplying power and cannot automatically resume power supply when the input current restores to the normal range. |
Output overvoltage protection | In this protection state, the power adapter stops supplying power intermittently. When the output voltage restores to the normal range, the power adapter automatically resumes power supply. |
Output overcurrent protection | In this protection state, the power module supplies power intermittently. When the output current is limited within a range, the power module automatically resumes power supply. |
Output short-circuit protection | In this protection state, the power module supplies power intermittently. When the short circuit is removed, the power module automatically resumes power supply. |
Overtemperature protection | When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply. |
Heat dissipation | Back-to-front airflow |
Hot swapping | The power module is hot swappable. |