FAQ-How user without domain name could access to AR router?

Issue Description FAQ-How user without domain name could access to AR router? Solution FAQ-How user without domain name could access to AR router? A: The common configuration is as following. radius-server template domain_test radius-server shared-key cipher %@%@&N=i)rz0;DEvm/AAPN|*KVzI%@%@ radius-server authentication 172.1.1.10 1812 weight 80 radius-server accounting 172.1.1.10 1813 weight 80 undo radius-server user-name domain-included aaa authentication-scheme domain_test authentication-mode radius accounting-scheme domain_test accounting-mode radius accounting start-fail...

IPsec tunnel not being up between AR router and another vendor router

Issue Description   IPsec tunnel not being up between AR router and other vendor router Handling Process   1) I checked the IPsec configuration on both AR router and other vendor router , and at first Phase 1 wasn’t up and after matching all parameters on both sides , phase1 was UP but still tunnel is still down 2) We checked the “...

OSPF Neighbor Relationship Flapping Caused by an Unstable Link

Issue Description   Applicable Products and Versions: In this example, the switches support Open Shortest Path First (OSPF). Table 4-1 describes the versions and products that support OSPF. Table 4-1 Product and version support for OSPF Networking: As shown in Figure 4-1, the switch directly connects to the NE40E. A VLANIF interface on the switch...

NE40E — clear alarm system config alarm for NE40E device

Issue Description   NE40E --- clear alarm system config alarm for NE40E device// MGF-NE40E-System config error Alarm Information Handling Process After checking the diagnostic file we found the following : ·       Device model and software version ·       ·       We checked the alarms regarding the system config alarm : Memory is abnormal ·       Display alarm active 130560/Independent/2020-08-19 10:28:02/-/0xffdc2048/hwSystemConfigError/Major/Start/ OID 1.3.6.1.4.1.2011.5.25.219.2.11.1 The system configuration is incorrect. (EntityTrapFaultID=144133) ·       Display...

Portal Authentication Fails Between Agile Controller-Campus and the ME60

Issue Description Portal authentication fails to be configured for the interconnection between Agile Controller-Campus running V100R002C10SPC403 and the ME60. A message indicating that the authentication fails is displayed on the Portal page. Handling Process 1. Check RADIUS logs. According to the logs, the authentication succeeds. 2. Capture information on the ME60. It is found that...

ONTs doesnt get IP addresses with option82

Issue Description   Client want to switch users for DHCP L2 with option82. After they enabled option82 the end users does not get IP. Alarm Information VERSION : MA5600V800R017C10 PATCH   : SPH202 PRODUCT : MA5683T Handling Process   Collect the details on the OLT (config)#scroll (config)#display patch all (config)#display board 0 (config)#display time (config)#display version (config)#display current-configuration (config)#display log all (config)#display log failure (config)#display alarm active all (config)#display alarm...

The NE40E IPoE Terminal Is Slow in Obtaining IP Addresses

Issue Description Device model: NE40E-X8 Software version: V600R009C20SPC600 Symptom: An IPoE terminal is slow in obtaining IP addresses, taking over 20 minutes. Handling Process 1.Log in to the NE40E to check the cause of the user online failure. It is found that the DCHP server times out in waiting for packets sent from DHCP...

NE40E-X8s Fail to Use a Super Password

Issue Description Before cutover, a customer logs in to an NE40E-X8 using SSH. A default password can be used to increase the level of user login permissions. After the NE40E-X8 is upgraded, the customer cannot use the default password to increase the level of user login permissions.   Alarm Information When the...

NE40E Esight Netstream NTA Traffic Statistics Inconsistency

Issue Description Problem: Esight Monitoring Fails to show Valid and Consistent Traffic figures on NE40E with Netstream Configured. Although sampling rate had been made more frequent to enhance the traffic accuracy on Esight, valid data and statistic analysis  still can not be shown. Handling Process Configuration of Netstream Parameters following the Manuals. Beware that the...

After service cutover is performed on the downstream service interface of an ME60, the original users cannot go online.

Issue Description After service cutover is performed on the downstream service interface of an ME60, the original users cannot go online.   Handling Process Run thedis access-user interface GigabitEthernet x/x/x.300Xcommand on the ME60 to check that no users go online from the service interface where cutover is performed. Run thedis aaa online-fail-record...