S5731-S24T4X-AC
Huawei S5731-S24T4X-AC switch supports 24 10/100/1000BASE-T ports, 4 10GE SFP+ ports, 2 hot swappable AC/DC power supplies, 1 AC equipped
- Description
- DATASHEET
- Download
- Reviews (1)
Description
S5731-S24T4X-AC overview
Huawei S5731-S24T4X-AC with 24 10/100/1000BASE-T ports, 4 10GE SFP+ ports, is one of the Huawei S5731-S series switches. The S5731-S series switches were developed based on next-generation high-performing hardware and the Huawei Versatile Routing Platform (VRP).
The CloudEngine S5731-S supports simplified operations and maintenance (O&M), intelligent stack (iStack), flexible Ethernet networking. It also provides enhanced Layer 3 features and mature IPv6 features. The CloudEngine S5731-S can be used in various scenarios. For example, it can be used as an access or aggregation switch on a campus network or as an access switch for Metropolitan Area Network.
S5731-S24T4X-AC quick spec
24 10/100/1000BASE-T ports
4 10GE SFP+ ports
1 AC equipped
Forwarding performance: 96 Mpps
Switching capacity: 128 Gbps/672 Gbps
S5731-S24T4X-AC appearance and structure
1. Twenty-four 10/100/1000BASE-T ports | 7. Ground screw |
2. Four 10GE SFP+ ports | 8. Fan module slot 1 |
3. One console port | 9. Fan module slot 2 |
4. One ETH management port | 10. Power module slot 1 |
5. One USB port | 11. Power module slot 2 |
6. One PNP button |
Item | S5731-S24T4X-AC |
Forwarding performance | 96 Mpps |
Switching capacity | 128 Gbps/672 Gbps |
Fixed port | 24 10/100/1000BASE-T ports, 4 10GE SFP+ ports |
Power supply type | 150 W AC (pluggable) 600 W AC (pluggable) 1000 W DC (pluggable) |
Rated voltage range | AC input (150 W AC ): 100 V AC to 240 V AC, 50/60 Hz AC input (600 W AC ): 100 V AC to 240 V AC, 50/60 Hz DC input (1000 W DC): -48 VDC to – 60 V DC |
Maximum voltage range | AC input (150 W AC ): 90 V AC to 264 V AC, 47 Hz to 63 Hz AC input (600 W AC ): 90 V AC to 290 V AC, 45 Hz to 65 Hz High-voltage DC input (600 W AC): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification) DC input (1000 W DC): -38.4 V DC to -72V DC |
Maximum power consumption | 114 W |
Noise | Under normal temperature (sound power): 57.5dB (A) Under high temperature (sound power): 70.9dB (A) Under normal temperature (sound pressure): 47.5dB (A) |
Operating temperature | 0-1800 m altitude: -5°C to +45°C 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m. |
Storage temperature | -40℃ to +70℃ |
Relative humidity | 5% to 95% (non- condensing) |
Surge protection specification (service port) | Common mode: ±6 kV |
Surge protection specification (power port) | AC power port: ±6 kV in differential mode, ±6 kV in common mode DC power port: ±2 kV in differential mode, ±4 kV in common mode |
Heat dissipation | Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans |
Dimensions (W x D x H) | 442 mm x 420 mm x 43.6 mm |