ZXA10 C600/C650/C680 board comparison:
| Card Type | Card Model | Card Name | Functions |
| Switching and control card | SFUL | Type-L switching and control card | ZXA10 C600/C650 switching and control card |
| Provides the following interfaces: | |||
| 1 out-of-band management port (MGMT) | |||
| 1 maintenance serial port (CONSOLE) | |||
| 1 USB interface | |||
| 1 mirror diagnosis network port (DIAG) | |||
| 1 debugging port (ODB) | |||
| Supports load sharing mode. | |||
| Supports hot swapping. | |||
| Supports 4 OLT slices. | |||
| SFULV | Type-LV switching and control card | ZXA10 C600/C650 switching and control card | |
| Provides the following interfaces: | |||
| 1 out-of-band management port (MGMT) | |||
| 1 maintenance serial port (CONSOLE) | |||
| 1 USB interface | |||
| 1 mirror diagnosis network port (DIAG) | |||
| 1 debugging port (ODB) | |||
| Supports load sharing mode. | |||
| Supports hot swapping. | |||
| Supports 8 OLT slices. | |||
| SFUH | Type-H switching and control card | ZXA10 C600/C650 switching and control card | |
| Provides the following interfaces: | |||
| 1 out-of-band management port (MGMT) | |||
| 1 maintenance serial port (CONSOLE) | |||
| 1 USB interface | |||
| 1 mirror diagnosis network port (DIAG) | |||
| 1 debugging port (ODB) | |||
| 4 10GE/GE Ethernet uplink ports | |||
| Supports load sharing mode. | |||
| Supports hot swapping. | |||
| Supports 4 OLT slices. | |||
| SFUHV | Type-HV switching and control card | ZXA10 C600/C650 switching and control card | |
| Provides the following interfaces: | |||
| 1 out-of-band management port (MGMT) | |||
| 1 maintenance serial port (CONSOLE) | |||
| 1 USB interface | |||
| 1 mirror diagnosis network port (DIAG) | |||
| 1 debugging port (ODB) | |||
| 4 10GE/GE Ethernet uplink ports | |||
| Supports load sharing mode. | |||
| Supports hot swapping. | |||
| Supports 8 OLT slices. | |||
| Control card | IMEP | Type-P control card | ZXA10 C680 control card |
| Provides the following interfaces: | |||
| 1 out-of-band management port (MGMT) | |||
| 1 maintenance serial port (Console) | |||
| 1 USB interface | |||
| 1 mirror diagnosis network port (DIAG) | |||
| 1 debugging port (ODB) | |||
| Supports hot swapping. | |||
| Supports 8 OLT slices. | |||
| Switching card | SWUM | Type-M switching card | ZXA10 C680 switching card |
| Supports load sharing mode. | |||
| Supports hot swapping. | |||
| Clock sub-card | CISA | Clock sub-card | ZXA10 C600/C650/C680 clock sub-card |
| Installed on the SFUL/SFULV, SFUH/SFUHV and the IMEP card. | |||
| Supports network clock and time synchronization. The daughter card is mandatory to implement IEEE 1588 or 1PPS+TOD time synchronization. | |||
| Does not support hot swapping. | |||
| Power card | PRVR | Type-R DC power interface card | ZXA10 C600/C650/C680 DC power card |
| Provides one –48V DC input interface. Each channel supports maximum 60A current. | |||
| Supports hot swapping. | |||
| Clock interface card | CLCT | Type-T clock interface card | ZXA10 C600/C650/C680 clock interface card |
| Provides the following interfaces: | |||
| 2 120 Ω BITS clock/1PPS+TOD time input interface (CLKI1 and CLKI2) | |||
| 1 120 Ω BITS clock/1PPS+ToD time output interface (CLKO) | |||
| 1 common maintenance serial port (COM)/1 digital input interface+1 digital output interface | |||
| 1 out-of-band NM interface(MGMT)/2 digital input interfaces | |||
| Supports hot swapping. | |||
| Service card | GFGH | 16-port GPON subscriber card | Supports 16 GPON SFP interfaces. |
| Maximum optical split ratio: 1:128. | |||
| Supports optical power monitoring. | |||
| Supports the ALS function of optical modules. | |||
| Supports hot swapping. | |||
| GFTH | 16-port XGS-PON subscriber card | Supports 16 XGS-PON SFP+ interfaces. | |
| Maximum optical split ratio: 1:256. | |||
| Supports optical power monitoring. | |||
| Supports the ALS function of optical modules. | |||
| Supports hot swapping. | |||
| GFXH | 16-port XG-PON subscriber card | Supports 16 XG-PON SFP+ interfaces. | |
| Maximum optical split ratio: 1:256. | |||
| Supports optical power monitoring. | |||
| Supports the ALS function of optical modules. | |||
| Supports hot swapping. | |||
| GFBH | 16-port XG-PON & GPON Combo subscriber card | Supports 16 XG-PON & GPON SFP+ hybrid interfaces. | |
| Maximum optical split ratio of GPON: 1:128. | |||
| Maximum optical split ratio of XG-PON: 1:128. | |||
| Supports optical power monitoring. | |||
| Supports the ALS function of optical modules. | |||
| Supports hot swapping. | |||
| GFCH | 16-port XGS-PON & GPON Combo subscriber card | Supports 16 XGS-PON & GPON SFP+ hybrid interfaces. | |
| Maximum optical split ratio of GPON: 1:128. | |||
| Maximum optical split ratio of XGS-PON: 1:128. | |||
| Supports optical power monitoring. | |||
| Supports the ALS function of optical modules. | |||
| Supports hot swapping. | |||
| EFTH | 16-port 10G-EPON subscriber card | Supports 16 10G-EPON SFP interfaces. | |
| Maximum optical split ratio: 1:256. | |||
| Supports optical power monitoring. | |||
| Supports the ALS function of optical modules. | |||
| Supports hot swapping. | |||
| Ethernet interface card | XFTO | 8-port 10GE Ethernet optical interface card | Supports 8 10GE SFP+/GE SFP Ethernet interfaces. |
| Supports optical power monitoring. | |||
| Supports uplink Ethernet communication. | |||
| Supports hot swapping. | |||
| Supports the SyncE function. | |||
| XFTH | 16-port 10GE Ethernet optical interface card | Supports 16 10GE SFP+/GE SFP Ethernet interfaces. | |
| Supports optical power monitoring. | |||
| Supports uplink Ethernet communication. | |||
| Supports hot swapping. | |||
| Supports the SyncE function. | |||
| XFPH | 16-port P2P Ethernet optical subscriber card | Supports 16 10GE SFP+/GE SFP P2P Ethernet interfaces. | |
| Supports optical power monitoring. | |||
| Supports P2P Ethernet access. | |||
| Supports hot swapping. | |||
| Supports the SyncE function. | |||
| Supports 1588v2. | |||
| PFEK | 48-port P2P Ethernet optical subscriber card | Supports 24 Compact SFP (CSFP) P2P GE/FE optical modules (supports 48-port P2P users). | |
| Supports 24 GE SFP/FE SFP Ethernet modules (supports 24 users). | |||
| Supports optical power monitoring. | |||
| Supports P2P Ethernet access. | |||
| Supports hot swapping. | |||
| Supports the SyncE function. | |||
| Backplane | MVET | 21″ ZXA10 C600 backplane | 21″ backplane for the ZXA10 C600. |
| MVIT | 19″ ZXA10 C600 backplane | 19″ backplane for the ZXA10 C600. | |
| MRIT | 19″ ZXA10 C650 backplane | Backplane for the ZXA10 C650. | |
| MUEZ | 21″ ZXA10 C680 backplane | Backplane for the ZXA10 C680. | |
| Fan unit | FAN-C600/21L-MA | 21″ ZXA10 C600 fan unit | ZXA10 C600 21″ fan unit. |
| Configured with built-in fan control card FCVD. | |||
| Configured with eight fans arranged in two rows. | |||
| Supports hot swapping. | |||
| FAN-C600/19L-MA | 19″ ZXA10 C600 fan unit | ZXA10 C600 19″ fan unit. | |
| Configured with built-in fan control card FCVD. | |||
| Configured with six fans arranged in two rows. | |||
| Supports hot swapping. | |||
| FAN-C650-MA | 19″ ZXA10 C650 fan unit | ZXA10 C650 19″ fan unit. | |
| Configured with built-in fan control card FCRD. | |||
| Configured with six fans arranged in two rows. | |||
| Supports hot swapping. | |||
| FAN-C680/21L-T-MA | 21″ ZXA10 C680 fan unit at the top | ZXA10 C680 21″ fan unit at the top. | |
| Configured with built-in fan control card FCVD. | |||
| Configured with eight fans arranged in two rows. | |||
| Supports hot swapping. | |||
| FAN-C680/21L-B-MA | 21″ ZXA10 C680 fan unit at the bottom | ZXA10 C680 21″ fan unit at the bottom | |
| Configured with built-in fan control card FCVD. | |||
| Configured with eight fans arranged in two rows. | |||
| Supports hot swapping. | |||
| FAN-C680/21L-MID-MA | 21″ ZXA10 C680 fan unit in the middle | ZXA10 C680 21″ fan unit in the middle. | |
| Configured with built-in fan control card FCUD. | |||
| Configured with two fans. | |||
| Supports hot swapping. |
If you have any questions, please feel free to contact: csd@telecomate.com