SSR2AUX

Huawei SSR2AUX is a system auxiliary interface board for Huawei OSN1500B. The AUX can be used on the OptiX OSN equipment series to provide various management interfaces and auxiliary interfaces.

SKU: 2015218 Category:

Description

SSR2AUX Version Description

 

The AUX is available in two functional versions, namely, R1 and R2. The difference between the two versions is whether the status of the Ethernet port connection can be checked.
Item Description
Functional version The AUX is available in two functional versions, namely, R1 and R2.
Difference
  • Checking of the Ethernet port connection status: The R2AUX supports the checking of the Ethernet port connection status, whereas the R1AUX does not.

 

SSR2AUX Functions and Features

 

The AUX provides various management and auxiliary interfaces for the system and provides the centralized backup for the +3.3 V power supply of the boards in the subrack.

 

Item AUX
Management interface
  • Provides the OAM/F&f interface, which supports the X.25 protocol.
  • Provides the 10M/100M interface.
Clock interface Provides two BITS clock input interfaces (CLK)and two BITS clock output interfaces (CLK)(impedance: 120 ohms).
Alarm interface Provides 3-input and 1-output alarm interfaces.
Commissioning interface Provides one commissioning interface COM.
Internal communication Realizes communication boards in the sub-rack.
Power supply backup and checking
  • Monitors the two independent –48 V power supplies and detects the overvoltage (–72 V) and undervoltage (–38.4 V) conditions.
  • Provides the centralized backup for the +3.3 V power supply of the boards in the subrack, which realizes the 1:N protection for the secondary power supply of each board. The power of the +3.3 V backup power supply is 80 W.
  • Detects the overvoltage (+3.8 V) and undervoltage (+3.1 V) conditions for the +3.3 V backup power supply.
Audible alarm Supports the audible alarm and the clearing of the audible alarm.
Ethernet port connection status checking The R2AUX supports the checking of the Ethernet port connection status.
Note: The COM interface is used for internal commissioning only. That is, the COM interface cannot be used for equipment monitoring. Otherwise, the Ethernet communication between boards may become abnormal.

NOTE:

To ensure normal conference calls, each conference call subnet can support a maximum of 10 concurrent conference calls. If there are more than 10 concurrent conference calls on a conference call subnet, divide the subnet into several ones.

 

SSR2AUX Valid Slots

The AUX can be installed in slot 10 in the subrack.

 

SSR2AUX Technical Specifications

The technical specifications of the AUX include the mechanical specifications and power consumption.

 

Mechanical Specifications

The mechanical specifications of the AUX are as follows:

Dimensions (mm): 25.4 (W) x 235.2 (D) x 128 (H) Weight: 1.0 kg

Power Consumption At room temperature (25°C), the maximum power consumption of the AUX is 19 W.