TNZ5TSC
Huawei OSN1800V 100G Tributary Service Processing Board TNZ5TSC, 03032LVV
Huawei
- Description
- DATASHEET
- Reviews (1)
Description
The available functional version of the TSC board is TNZ5.
Version description of the TSC board
Board |
Product Applicable-System Control Board-Initial Board Version Supported by System Control Board |
---|---|
TNZ5TSC |
1800 V-TNZ5UXCMS-V100R007C10 1800 V-TNZ8XCH-V100R009C00SPC700 |
Item |
TNZ5TSC |
||
---|---|---|---|
Basic functions |
Port Working Mode |
Supports the following service conversions:
Mapping path:
|
|
Cross-connect functionality |
Supports backplane cross-connections of one ODU4 or n ODUflex (n = (1-80)) signals from/to the cross-connect board. |
||
Service specifications |
Service types |
100GE: Ethernet service at a rate of 103.125 Gbit/s OTU4: OTN service at a rate of 111.81 Gbit/s When 100GE services are received on the client side and mapped into ODUflex, the client equipment must support flow control response. |
|
Service mapping mode |
100GE: Bit Transparent Mapping/ MAC Transparent Mapping |
||
Maximum frame length (MFL) for a port |
Ranges from 1518 bytes to 9600 bytes. |
||
Protection schemes |
Client 1+1 Protection |
Supported |
|
ODUk SNCP |
Supported |
||
Tributary SNCP |
Supported NOTE: Supports tributary SNCP protection only when the client-side service type is OTU4. |
||
LPT |
Not supported |
||
ALS |
Supports the ALS function on the client side when client services are non-OTN services. |
||
Synchronization |
Synchronous Ethernet |
Supports synchronous ethernet processing when 100GE(GFP-F) services are received on the client side. Supports synchronous ethernet transparent transmission when 100GE(GMP) services are received on the client side. |
|
IEEE 1588v2 |
Not supported |
||
G.8273.2 |
Not supported |
||
G.8275.1 |
Not supported |
||
Maintenance features |
Loopbacks |
Supports inloops and outloops on the client side. |
|
Pseudo random binary sequence (PRBS) test function |
Supports the PRBS test function on the client side only when receiving OTU4 services. |
||
Test frames |
Supports this function when receiving 100GE services on the client side. |
||
Delay measurement (DM) |
Supports DM. Specifically, the bidirectional delay between two tributary boards supporting DM can be measured, and the delay data is displayed on the NMS. |
||
Alarms and performance events monitoring |
|
||
OTN Overheads |
|
||
Outband DCN |
Supports ESC communication. NOTE: Supported when the client-side service type is OTU4. |
||
FEC Mode |
Supports ITU-T G.709-compliant forward error correction (FEC) encoding on the client side only when receiving OTU4 signals. |
||
Electrical-layer ASON |
Supported |
||
Typical Power Consumption (W) |
88.5 |
||
Maximum Power Consumptiona (W) |
98 |
||
Dimensions (W x H x D, unit: mm/in.) |
193.8 x 40.1 x 205.9 (7.6 x 1.6 x 8.1) |
||
Weight |
1.75 kg (3.86 lb.) |